Remove old non working pump Replace with same power/model for balanced system 3 year manufacturer’s warranty on pump 90 day warranty Upon arrival disconnected old sewer pump from union and lifted out of hole. Disconnected and removed old wire from control box. Installed new threaded adapter onto new pump and glued pipe into adapter. Ran wire from new pump into control box and hooked up. Lowered new pump into hole. Positioned pump in correct position and screwed union back together. Opened up gate valve to allow pump to flow. Restored power to pump, pump was not cutting on. After further inspection discovered actuator on control panel was burned up due to pump going bad. Customer will replace actuator. Hard wired pump to verify working correctly, pump cut on and worked properly when hard wired.