Examined machine. Filled and started cycled rack through- wash temp 140*. Rinse temp 190*. Drained unit and checked for bad elements. Found wash temp board no power out. 11-29-16 Examined unit. Fill tanks. Replaced temp controller and tested. Found float and probe assembly shorted out. Will Id part and order. When board shorted out, must have taken out probe. 1-4-17 Removed and replaced probe assembly. Tested unit for filling and heat. Right side wash tank, everything working correctly. Adjusted temp higher.