Service C.

Service C.


Job Checkin

Found signs where the fit vacuum breaker on JAC Dishwasher has been leaking. found the final rinse is working now. I will obtain a final rinse solenoid and 2 vacuum breaker and return. I did clean the wash tank float switch assy. Gus is not here today. I will obtain parts and return. 3/10/21 Arrived on site and installed replacement vacuum breaker on left of unit and solenoid valve on right of unit. tested unit ok for use and no leaks.