Arrived at location on 2/3/22 - Checked temperature on dishwasher and found thermistor is giving incorrect reading says 190 degrees but rinse water is only 160 degrees will need to order new thermistor and set thermostat to correct temperature. Returned to location on 2/14/22 - Replaced thermistor on rinse supply line and adjusted thermostat to highs set point still only getting 163 degrees on rinse temperature off off water inside dishwasher. Will order a new thermostat and second thermistor for tank. Returned to location on 2/28/22 - Replaced tank temperature probe and checked temperatures found tank is at 190 degrees. line to spray arms are 188 degrees and at point of contact on dishes 163 degrees called manufacturer and they said that machine is working correctly that you will have a 30 degrees drop from spray arms to dishes.