1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Job Locations
for lansdale, pa


Map of Lansdale PA
Service C.

Service C.


Job Checkin

Started the Dishwasher and let run. Final rinse starts at 188 ° and rinse pressure is 25 psi. Ran many trays through and okay. Temps okay. The drain sol valve is not working and is disconnected. one rinse arm is not working . Checked the pump motor and it''s spinning, Open and cleared out the piping to the pump and from the pump into the spray arms and the nozzles are open. Tested several times and still won't pump. Need pump and drain valve and the lock wash pins for the spray arms. The unit is in service and wash temps are okay. PER VIKTOR, QWP (expedited freight) ALL PARTS 12/13/18 Disassembled and removed old pretense pump and installed the new pump and wired it in . Zip tie in wires and head butt end terminals . Removed and installed the new drain valve and installed the 2 new wash arm blocks. Power on and let heat up and run cycles. Customer passing many dishes through unit and temps are good. pre wash is running and at 139F wash is 164°F pre rinse is 156 ° F and final rinse i