1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Job Locations
for lehighton, pa


Map of Lehighton PA
Service C.

Service C.


Job Checkin

checked out unit. set temp to 150 degrees and checked actual temp with meter. cycled off at 186 degrees. then set to 275 degrees and unit cycled off at 250 degrees. set to 350 which is what unit was set for upon arrival and unit cycled off at 298 degrees. checked temp control board and have proper voltage in. board is not operating correctly. do not have part on van stock. spoke to mike @Vulcan and got part #00-913149=temp control board. will order through shop and return. 5/16/18 Installed new Temp controller. Turn on. Let heat to 250. Cycled off at 230. Adjusted controller. Set to 350. Heated and is maintaining that temp. Back in Service.