1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Job Locations
for middletown, pa


Map of Middletown PA
Service C.

Service C.


Job Checkin

Upon arrival, both Reach-In Freezer units overheated and cycling on compressor overload. Customer stated kitchen A/C was not working and was in the midst of repair. Also stated filters were dirty and needed cleaned/replaced. Ambient temperature in kitchen 108°F at this time. Cooled off compressor manually and unit ran for 5-7 minutes and shut off again on overload. Compressor ampdraw good and windings checking out good, units not low on refrigerant. Advised customer of same issue with both units and advised they should leave units off to allow compressors to cool entirely until kitchen at appropriate conditioned temperature. Units off at this time, product removed, and customer will power back on once compressors have time to cool and kitchen A/C working properly.