Tab on ice machine thickness probe was broken so I replaced it. Watched one batch and ice was too thick so I adjusted probe and watched 2 more batches drop. Ice thickness was not changing and new probe was not responding properly. I had another probe so I put it in and watched a couple batches. Ice thickness is now okay. ***mileage and travel on work order # 170293***