1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Job Locations
for new holland, pa


Map of New Holland PA
Service C.

Service C.


Job Checkin

Arrived, stated CHA Dishwasher unit is not making temp, dishes not being cleaned properly. checked unit over, found rinse and wash temps are low. final rinse temp is ok. removed top cover, found no amp draw on wash tank elements, contactors are pulled in. found 1 90 amp fuse is blown. causing the elements to not heat. did shut off all breakers. checked components, burnt wiring at blown fuse. contactors are ok. checked each wash element, each ohms out ok. turned unit back on. did leave 100 amp breaker for wash tank off. will order fuses and fuse block. will need to replace wiring as well. please check amp draw on each element individually after repairs are made, check if any leg on any element increases amp draw after it gets heated up. did also check all pumps, all pumps are running and pulling correct amps. will order parts and return. 2/15/21 Arrived, shut all breakers off to unit. remove top cover. verify no voltage. remove fuses and fuse block for wash tank heaters. install new fu