Arrived at location on 11/28/22 - Checked dish washer to see if any damage from fire customer had at site checked all wiring etc did not see any burnt cycled unit on filled ok heating element pulling 12 amps per leg unit ran thru cycles ok note float switch is not working right heat will cycle before switch is engaged will get price of float switch assembly. Returned to location on 12/7/22 - Replaced float assembly and tested unit made adjustments as needed to get unit to stop filling before hit overflow stand pipe tested unit tested ok