Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Goodman AC unit. I found the system has a leak. The customer just filled it up last year. I gave the customer options to repair and replace, but they will let us know.

I completed a diagnostic on a Goodman AC unit. I found the system has a leak. The customer just filled it up last year. I gave the customer options to repair and replace, but they will let us know.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Ruud AC unit. I found the contactor pitted. I was unable to look at the furnace due to the crawl space being too small. Can’t get a new furnace down or out. Flex duct is all bad and half of it is not connected. Unable to provide service.

I completed a diagnostic on a Ruud AC unit. I found the contactor pitted. I was unable to look at the furnace due to the crawl space being too small. Can’t get a new furnace down or out. Flex duct is all bad and half of it is not connected. Unable to provide service.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Carrier AC unit and a Janitrol furnace. I found the the evaporator coil and filter plugged. I also found the contracted pitted and the dual cap was bad. I washed the unit. The system appears to be low on refrigerant, but the evaporator coil needs to be cleaned first. The condenser fan is also over amping and will most likely fail soon. I advised the customer the systems are at the end of their lives and recommended in placements.

I completed a diagnostic on a Carrier AC unit and a Janitrol furnace. I found the the evaporator coil and filter plugged. I also found the contracted pitted and the dual cap was bad. I washed the unit. The system appears to be low on refrigerant, but the evaporator coil needs to be cleaned first. The condenser fan is also over amping and will most likely fail soon. I advised the customer the systems are at the end of their lives and recommended in placements.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Carrier AC unit and a Janitrol furnace. I found the the evaporator coil and filter plugged. I also found the contracted pitted and the dual cap was bad. I washed the unit. The system appears to be low on refrigerant, but the evaporator coil needs to be cleaned first. The condenser fan is also over amping and will most likely fail soon. I advised the customer the systems are at the end of their lives and recommended in placements.

I completed a diagnostic on a Carrier AC unit and a Janitrol furnace. I found the the evaporator coil and filter plugged. I also found the contracted pitted and the dual cap was bad. I washed the unit. The system appears to be low on refrigerant, but the evaporator coil needs to be cleaned first. The condenser fan is also over amping and will most likely fail soon. I advised the customer the systems are at the end of their lives and recommended in placements.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on an Amana AC unit. I found the condenser and filter was clogged. The customer said he would wash himself. The customer has an oil furnace, which we do not work on. I checked the system again to make sure everything else was good before departure.

I completed a diagnostic on an Amana AC unit. I found the condenser and filter was clogged. The customer said he would wash himself. The customer has an oil furnace, which we do not work on. I checked the system again to make sure everything else was good before departure.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Ducane AC unit. I found the dual cap dead and the contractor pitted. I gave the customer options and they want to move forward with a replacement unit.

I completed a diagnostic on a Ducane AC unit. I found the dual cap dead and the contractor pitted. I gave the customer options and they want to move forward with a replacement unit.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Goodman AC unit. I found the compressor coming on but not pumping any refrigerant. The house has two systems, and the customer decided to replace both systems instead of repairs.

I completed a diagnostic on a Goodman AC unit. I found the compressor coming on but not pumping any refrigerant. The house has two systems, and the customer decided to replace both systems instead of repairs.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a York air conditioning unit. I found the blower motor is not coming on and if it does, only runs 20%. The blower has failed and the customer decided for us to replace the unit.

I completed a diagnostic on a York air conditioning unit. I found the blower motor is not coming on and if it does, only runs 20%. The blower has failed and the customer decided for us to replace the unit.

Hassan H.

Hassan H. Job Checkin

I gave an estimate for a Five Star 80% 70,000 BTU Gas Furnace and a Five Star 13 SEER 2 Ton Air Conditioner. Included with the installation is a free 1 year service maintenance agreement.


Hassan H.

Hassan H. Job Checkin

I completed a diagnostic service. I found that the blower wheel has come apart from the motor shaft and completely stripped the end that the shaft goes into. Quoting motor and wheel for this. A/C is located on the roof, advised client I would not be able to check anything on the A/C because there was no access to roof and I was not aware of rooftop unit beforehand.

I completed a diagnostic service. I found that the blower wheel has come apart from the motor shaft and completely stripped the end that the shaft goes into. Quoting motor and wheel for this. A/C is located on the roof, advised client I would not be able to check anything on the A/C because there was no access to roof and I was not aware of rooftop unit beforehand.

Hassan H.

Hassan H. Job Checkin

I gave an estimate on a Carrier 16 SEER 3.5 Ton Air Conditioner and a Carrier "Infinity Series" 80% 2 Stage Variable Speed 110,000 BTU Gas Furnace. Included in the estimate is a 1 year free service maintenance agreement.


Hassan H.

Hassan H. Job Checkin

I gave an estimate to install a Five Star 16 SEER 3 Ton Heat Pump. Included in the estimate is a 1 year free service maintenance agreement.


Hassan H.

Hassan H. Job Checkin

I performed a diagnostic on a Goodman AC. I determined that Drain was clogged and blower had a dead cap. I replaced cap and added new drain. Cycled and monitored the system. Operating normally at this time

I performed a diagnostic on a Goodman AC. I determined that Drain was clogged and blower had a dead cap. I replaced cap and added new drain. Cycled and monitored the system.  Operating normally at this time

Hassan H.

Hassan H. Job Checkin

I performed a diagnostic on a Goodman AC. I determined that the fan was going out and the contractor was bad. Customer did not want to replace contractor.

I performed a diagnostic on a Goodman AC. I determined that the fan was going out and the contractor was bad. Customer did not want to replace contractor.

Hassan H.

Hassan H. Job Checkin

I performed a diagnostic on two Trane air conditioners. I found that the main system was very low on coolant. The second system had a clogged drain and was leaking water from the humidifier. I attempted to clear the drain but it was completely clogged. The customer decided to replace both units and a furnace.

I performed a diagnostic on two Trane air conditioners.  I found that the main system was very low on coolant.  The second system had a clogged drain and was leaking water from the humidifier.  I attempted to clear the drain but it was completely clogged.  The customer decided to replace both units and a furnace.