1570 Old York Road
Abington, PA 19001
215-659-4343

Local Reviews
for philadelphia, pa

Rated 4.9 out of 5 stars based on 130 customer reviews

Excellent service

Professional and friendly


Response from Chud Air Conditioning & Heating:

Your 5-star review means a lot to us!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super Service.

Fantastic Experience.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Louise, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

explained service contract effectively, clearly.


Response from Chud Air Conditioning & Heating:

Ed, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

GREAT ALL AROUND!!!

PERFECT!!!


Response from Chud Air Conditioning & Heating:

Louise, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Paul is great very knowledgeable


Response from Chud Air Conditioning & Heating:

5 stars, thank you Edward!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent job


Response from Chud Air Conditioning & Heating:

Derek, thank you for leaving Chud a 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Prompt, professional and friendly.


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Keisha.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Michael, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service


Response from Chud Air Conditioning & Heating:

Nancy, thank you for leaving Chud a 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job


Response from Chud Air Conditioning & Heating:

5 stars, thank you Nancy!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great survive clean job


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Joe.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fair price,good Service

very Respectful would use again


Response from Chud Air Conditioning & Heating:

Cecelia, we are happy to see you happy with our services and would use us again! We always strive for 5 stars, please give us a call at 215-659-4343 to let us know what we could have done to get that 5th star.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

On time Courteous Job well done Will repeat


Response from Chud Air Conditioning & Heating:

Samuel, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

FRANK ALWAYS DOES A PROFESSIONAL JOB

VERY SATISFIED


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!! 👍

Frank was on time and courteous of my house. He explained in detail the problem and how he was going to fix it. The company is a better company for having him on staff.


Response from Chud Air Conditioning & Heating:

Eric, we’ll make sure to pass your kind words along to Frank, who we know will be delighted to read your comments.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for philadelphia, pa

Shane A.

Shane A. Job Checkin

Model # RG250L6N Serial # YE49769843 Customer called about no hot water. The pilot was not lightning because the gas valve is stuck shut. Water heater is 4 month old and under warranty. The homeowner is going to reach out to the original installer before he makes a decision on who is going to replace the gas valve and pilot assembly.


Thomas W.

Thomas W. Job Checkin

Performed preventative maintenance on a Goodman AC system. Model number: GSX160301FG. Serial number: 2011193841. Upon arrival the unit was off. Turned the uni5 on at the thermostat. Went downstairs to the system and watched the unit run. Turned the unit off at the switch. Removed the panel to the evaporator coil. Inspected the coils for any dust build up. Poured water into the condensate trap and watched it drain properly. Poured water into the condensate pump and watched it pump out properly. Removed the panels to the furnace. Checked the electrical connections to make sure they were properly secure. Checked the blower motor and fan for any dust build up. Replaced the 16x20x1 filter. Took an amp draw of the motor. Running within the manufacture’s specs. Placed the panels back on the unit and watched it run. Went outside to the condenser and watched it run. Checked the coils for any dirt build up. Removed the panel. Checked the contactor and capacitor. Both are running within the manuf


Shane A.

Shane A. Job Checkin

Armstrong Air Model # 4AC13L36P-10A Serial # 1920D38088 Completed a preventative maintenance on a newer air conditioner. We installed the evaporator coil in 2022 and another company installed the outdoor unit. When I arrived I took a split temperature and the reading was 20 degrees. I changed the 16x25x1 filter then I made sure the drain wAs operating properly. After that I went outside and did an amperage readings on the condenser fan motor .77 amps rated for 1.1 amps the compressor 8.7 amps rated for 16.7. The contactor and capacitor are both in good condition and both are operating properly. System is new and operating properly at this point. Customer prepaid for chud club membership is the upcoming season.


Thomas W.

Thomas W. Job Checkin

Performed preventative maintenance on Lennox heat pump, model number: HP29-036-5P, serial number: 5805A45695. Upon arrival the unit was on, I adjusted the thermostat to keep the ac running. Changed the 20x20x1 filter supplied by chud. Checked the condensate pump to make sure the water was pumping out properly. Checked the fan and motor for any dirt build up. Went outside to the condenser and watched it run. Checked the coils for any dirt build up. Removed the panel. Checked the contactor and capacitor, both running within the manufacture’s specs. Took an amp draw of the fan, .8 amps.n took an amp draw of the compressor, 7.5 amps. Placed the panel back on the unit and watched it run. Took a temp split of 19°. System is running properly at this time. Performed preventative maintenance on a air temp heat pump. Model number: VT5BD-060K. Serial number: N/A. Upon arrival the unit was on at the thermostat. I adjusted the temperature on the thermostat to keep it running. Changed the 20x20x1


Matthew M.

Matthew M. Job Checkin

Completed Goodman system installation. Installed furnace, condenser, and evaporator coil. Adapted to all existing connections. Ran new pvc drain to new condensate pump. Ran new flue pipe, adapted to gas line with new gas cock. Adapted to ductwork with new plenum. Replaced thermostat with Honeywell T4. Outside replaced disconnect box, whip, and pad. Added 16x25x1 filter rack. Cycled and tested, system working properly at this time. FINANCING


Shane A.

Shane A. Job Checkin

Manufacturer Arcoaire Model # CF36BBCA1A Serial # W1B8568772 Customer call about their thermostat being blank. When I arrived the door was not on correctly, and the door switch was not closed all the way. The gas company was looking for leaks and did not put the door back on properly. System is operating properly at this point.


Matthew M.

Matthew M. Job Checkin

Completed 50 gal Bradford white water heater installation. Adapted to existing water lines, flue, and gas. Bled air from all lines. Cycled and tested, system working properly at this time. Water heater paid in full. Will need to schedule dryer vent cleaning and repair. See estimate.


Thomas W.

Thomas W. Job Checkin

Performed preventative maintenance on a Lennox AC system. Model number: 13ACX-030-230-17. Serial number: 1914K36491. Upon arrival the AC was off. Turned the unit on at the thermostat. Went downstairs to the unit and watched it run. Turned the unit off at the switch. Opened the panel to the evaporator coil. Inspected the coils for any dust build up. Poured water into the condensate trap and watched the water drain properly. Poured water into the condensate pump and watched it pump out properly. Removed the panels to the furnace. Checked the electrical connections to make sure they were properly secure. Checked the blower motor and fan for any dust build up. Checked the capacitor on the blower motor. Running within manufacture’s specs. Homeowner recently changed the filter. Took an amp draw for the blower motor. Running within manufacture’s specs. Placed the panels back on the unit and watched it run. Went outside to the condenser. Unit was not running. Went down to the breaker panel and


Thomas W.

Thomas W. Job Checkin

Performed preventative maintenance on a Coleman AC system. Model number: TC4B3621H. Serial number: W1F8887919. Upon arrival the unit was on at the thermostat. I adjusted the temperature so the AC will keeping running. Went downstairs to the unit and watched it run. Turned the unit off at the switch. Checked the filter. Customer recently changed the filter so it is good. Removed the panel to the evaporator coil. Poured water into the condensate trap and watched it drain into the gravity drain line. Removed the panels to the furnace. Checked all electrical connections to make sure they are properly secure. Checked the capacitor for the fan motor. It is starting to get rusted, I recommend replacement either now or in the fall for the heater maintenance. Checked the blower motor and fan for any dust build up. Took an amp draw for the blower motor. Running within the manufacture’s specs. Placed the panels back on the unit and watched it run. Went outside to the condenser and watched it run.


Shane A.

Shane A. Job Checkin

Manufacturer Coleman Model # CC7B3621SA Serial # W1E9924764 Replaced condenser fan motor and fan blade under warranty Then completed a air conditioner maintenance. Changed out16x25x1 filter. The split temperature was 20 which is perfect. Then I performed a amperage readings on the condenser fan motor . 4 amps and the compressor at 7.8 amps made sure condensate pump is working. System is operating properly at this time.


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a Goodman ac system. Model #gsx130241ed, serial # 1704291403. Upon arrival the thermostat was turned off. I powered the system down at the furnace and removed the access panels. The Evaporator coil’s are clean and in good condition. I tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. I replaced the 16x25x1 pleated air filter supplied by the homeowner. I checked all electrical connections to ensure that they are secure and in good condition. I re attached the access panels and powered the system backup. I called for ac and observed the system starting normally. The condenser coils are clean and in good condition. The condenser amp draws are.52 for the fan and 4.6 for the compressor. The temperature split is at a 20° differential. The system is operating properly at this time. 1 Year CCM Maintenance Membership Membership includes: (1) Spring AC Maintenance (1) Fall Heating


Paul A.

Paul A. Job Checkin

Customer went with a new system


Keith R.

Keith R. Job Checkin

Perf A first floor dryer vent cleaning. Dryer vent,duct,flex hose, lint trap and booster fan are all clear of lint and debris at this time. Dryer and booster fan are both functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Jonathan C.

Jonathan C. Job Checkin

Replaced condenser coil under warranty. Pressure tested system with 350 psi for 30 minutes and system held pressure the whole time. Pulled system into a deep vacuum down to 500 microns per factory specifications. Charged system to factory charge of 4lbs 14oz with fresh R 410a refrigerant. Performed a temperature split on both supply and return ducts and I received an 18 degree temperature differential which is right on target. System is operating properly at this time.


Paul A.

Paul A. Job Checkin

Customer had appointments come in. She will get back to us.