Quick response to no heat.

No heat in the house. CHUD's tech, Frank arrived earlier than promised and restored our heat. Frank took his time and explained our options in a competent and friendly manner. CHUD is now my HVAC provider of choice.


Response from Chud Air Conditioning & Heating:

Hi Mike, we appreciate the good review. Chud works hard to create a good experience and reviews like this make it all worth it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very good service


Response from Chud Air Conditioning & Heating:

Philip, thank you for leaving Chud a 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service


Response from Chud Air Conditioning & Heating:

5 stars, thank you Phillip!

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service


Response from Chud Air Conditioning & Heating:

5 stars, thank you Robert!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Edward.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Frank was very good and I rate him a 10


Response from Chud Air Conditioning & Heating:

Edward & Lorraine, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service & price

Couldn’t ask for anything better


Response from Chud Air Conditioning & Heating:

James, thank you for the kind words & 5 star review! We are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service


Response from Chud Air Conditioning & Heating:

Gladys thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and Frank was awesome


Response from Chud Air Conditioning & Heating:

Prateek, thank you for leaving Chud a 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Extremely thorough and timely service!


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience, Michelle, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional service

Professional service!


Response from Chud Air Conditioning & Heating:

Hi James, what would make you give us that 5th star? Please give us a call to discuss, 215-659-4343.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Excellent service excellent technician


Response from Chud Air Conditioning & Heating:

Thank you for the 5-star review. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great experience. So much better than Dryer Duct Pros


Response from Chud Air Conditioning & Heating:

5 stars, thank you Tom! The Chud team appreciates it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

No problem


Response from Chud Air Conditioning & Heating:

5 stars, thank you Robert!

  • Overall Experience
  • Quality
  • Price
  • Convenience

?

Very knowledgeable


Response from Chud Air Conditioning & Heating:

5 stars, thank you Robert!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for philadelphia, pa

Frank B.

Frank B. Job Checkin

Customer called for heater short cycling. This is a one pipe boiler system. System is short cycling due to the wire harness shorting out for the electric flue damper. Will need to replace the wire harness to fix the current issue with the system. Recommend boiler maintenance as well due to major dirt buildup within the system. Model #AWI28SNST1PSU Serial #CROWNB000453032


Frank B.

Frank B. Job Checkin

Customer called for no heat upon inspection I restarted the system and it started without issue. Customer mentioned the system has been having issue once a season at least and would like a quote for replacement. Performed preventative maintenance instead for the time being. Replaced the non-existing air filter 16x25x1. Inspected all the electrical components. Confirmed proper high and low voltages. System had s temperature rise of 57°. Cleaned the burners, flame sensor and burner compartment. Performed a combustion analysis on the system. System is operating at 78.6% efficiency with a CO level of 43ppm. System is operating in fair condition at this time.


Frank B.

Frank B. Job Checkin

Customer called for heater not working properly. Upon inspection I found the furnace not recognizing the flames present. Pulled the flame sensor and cleaned it again due to some charing at the top. After it was cleaned again system started up just fine without issue with multiple restarts. No charge due to maintenance was just performed. System is operating properly at this time. Model #GMSS920603BNAA Serial #1408208185


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a Lennox furnace model #SL280UH090V36B-04, serial #5919408560. Upon arrival I called for heat and observed the system starting normally. I took a combustion analysis test and received the following readings, o2 is 10.5% and the co levels are 15ppm. The inducer amp draw is .18 and the blower motor amp draw is 4.9. I powered the system down and removed and cleaned carbon off of the flame sensor. Cleaned out the burners and burner box. Replaced the air filter size 16x25x1 and tested the drain line with several bottles of water. Checked the pressure switch for clogs and checked all electrical connections to ensure that they are secure and in good condition. The system is operating properly at this time.


Frank B.

Frank B. Job Checkin

Performed preventative maintenance on a standard gas furnace. Inspected all the electrical components. Confirmed proper high and low voltages. Replaced the standard 16x25x1 air filter. Cleaned the burners, flame sensor and burner compartment. Tested the amp draw for the blower and inducer. Both are operating within the manufacturer specifications. Performed a combustion analysis on the heater. System is operating at 82% efficiency and has a CO level of 27ppm. System is operating properly at this time. Model #2A7A3036A1000AA Serial #7504L7E3F


Paul A.

Paul A. Job Checkin

Installed new OAT/RH sensor, ebus cable, and 2 stage gas valve. Reconfigured unit using Wattmaster handheld device. Went through all heating and cooling setpoints and verified proper operation upon completion of repairs. ***BILLOUT*** Equipment worked on: AAON RTU M#RN-010-8-0-EB09-3L4, S#201604-ANGJ52142. Each of the (3) RTU’s take (4)-16x20x4 filters pleated (MERV 8) during maintenance.


Frank B.

Frank B. Job Checkin

Inspected all the electrical components. Customer replaced filter this month. Cleared all the tubing going to the inducer, pressure switches and collector box. Cleaned the burners, flame sensor and burner compartment. Tested the amp draw for the blower motor and inducer. Both are operating within the manufacturer specs. Made sure all drainage tubing was clear of debris. System had a temperature rise of 53°. Performed a combustion analysis on the furnace. System is operating at 94.6% efficiency with a CO level of 18ppm. System is operating properly at this time. Customer wanted to prepay for spring AC maintenance 2023. Customer total today was for fall maintenance 2022 and spring maintenance 2023. Customer due for renewal in fall 2023. Model #GMSS920603BNAA Serial #1408208185


Paul A.

Paul A. Job Checkin

Did a preventative maintenance on a Lennox gas furnace. During the maintenance I clean the flame sensor I also cleaned out the burner box in the blower motor housing. Also did an amp check on the inducer motor and the blower motor know everything is in range of the furnace specs. Also did a CO test which was seven and an O2 test which was 19. Also shop vac the entire unit out due to it being dirty and dusty. Also swapped out thermostat batteries. System is operating properly at this point. M#G50UH-48C-110-10 s#590El93


Frank B.

Frank B. Job Checkin

Completed preventative maintenance for high efficiency gas furnace. System is operating properly at this time. Cleaned the flame sensor. Cleaned out the burner box and burners. Checked for obstructions in the exhaust, intake, inducer, pressure switches, cold end header box and hoses. No obstructions found at this time. All electrical components are working properly at this point. Checked capacitor for inducer motor. Capacitor is operating properly within the rated microfarad range. Checked one inch air filter. Replaced customer supplied air filter. CO level is in the safe operation range (15ppm). Performed humidifier service. Replaced #35 water panel and cleaned out humidifier. Tested and checked it for leaks. No leaks present at this time. Thank you for your continued business with us! Model #ML193UH070XE36B-51 Serial #1719F44589


Matthew M.

Matthew M. Job Checkin

Replaced outdoor Fujitsu heat pump with new unit covered under warranty. Adapted to existing electric and line sets. Pressure tested and vacuumed all 4 zones. Tested and cycled mini split, mini split is operating properly at this time.


Frank B.

Frank B. Job Checkin

Performed preventative maintenance for gas furnace. Inspected all the electrical components. Confirmed proper high and low voltages. Customer replaces the standard air filter 16x25x1. Cleaned the burners, flame sensor and burner compartment. Performed a combustion analysis on the furnace. System is operating at 83% efficiency with a CO level of 17ppm. System had a temperature rise of 49° with the outdoor temperature at 77°. System is operating properly at this time. Found no sign of dye inside near the coil. Will need to inspect the condenser early spring to find where the refrigerant leak is coming from to repair it. Customer would like to take care of his own humidifier. The #35 water panel will be replaced by him once every season. Model #Tg8s100b12mp11 Serial #W1c8657380


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 2 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!


Paul A.

Paul A. Job Checkin

Did a maintenance on a new train system. Clean the flame sensor also cleaned out the burner compartment and the blower motor housing. Customer has 16 x 25 x 4 Merv 11 filter. Also did an amp drawling on the blower motor and the inducer motor which both are within the furnace specs. Also service the humidifier swapped out to number 35 panel also made sure the condensate pump was working and the humidifier is draining properly. Did a combustion test everything checks out. System is operating properly at this point. M#TUD2C080A9V4VB s#21392PY0GG


Jonathan C.

Jonathan C. Job Checkin

Performed maintenance on Lennox gas furnace. Customer does not have a heat pump. Cleaned burner rack and flame sensing rod. Changed 16x25x1 filter. Performed amp draw on inducer motor. Inducer motor nameplate amperage is rated at 1.75 I was reading 2.0 amps on my meter. I would recommend replacement of inducer motor. System is 14 years old, for best results I would recommend replacement of 90,000 btu furnace and 3 ton AC. 3 ton is large for this size home and customer could definitely lower to Proper size of 2.5 ton. Repair price for inducer motor replacement is $1,175.00 per RC. Collected $255.00. Tested and cycled furnace and it is operational at this time. Price to replace full system with 3 ton Goodman equipment is $9,275.00 Price to replace full system with 3 ton Lennox if available is $10,875.00


Frank B.

Frank B. Job Checkin

Performed preventative maintenance for standard gas furnace. This is a new chud install from fall 2021. Inspected all the electrical components. Confirmed proper high and low voltages. Cleaned the burners, flame sensor and burner compartment. Customer replaces air filter 16x25x1. Performed a combustion analysis on the furnace. System is operating at 84% efficiency with a CO level of 12ppm. System is operating properly at this time. No charge due to free with new install maintenance. Office will call to schedule a maintenance for spring 2023 for air conditioning. Model #GMES800804BNAA Serial #2110090740