1276 N. Warson
St. Louis, MO 63132
(314) 352-1111

Local Reviews
for ellisville, mo

Rated 4.0 out of 5 stars based on 3 customer reviews

Professional Service

I was impressed with the technicians and feel like he was very thorough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Bad information was given to me

Your tech told me a part was bad and would be 600 to repair . After getting diff company out, there was a paper stuck in part and guy removed in 5 mins and laughed at this. I feel taken and do not trust what was told obviously . Pls call me if you want

  • Overall Experience
  • Quality
  • Price
  • Convenience

higher than expected

had work done for half the price than quoted by your company

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for ellisville, mo

John M.

John M. Job Checkin

Cleaned & checked 2 gas furnaces. Inspected heat exchangers & flue venting. cleaned burners & flame sensors. Checked voltage & amp draw of motors. Test capacitors. Main system: Air filter clogged with dirt, causing blower to hit Rev limit. Pressure drop across filter: 1.15 inches water column. Replaced air filter. Clean and check humidifier. checked water flow and drain. Humidifier had no water flowing. I turned supply valve in and back out and valve unclogged. Water flow is currently fair. Humidifier pad coating ineffective. Replaced pad. Blower: 4.3A . Inducer: 0.26A . Lower level system: Replaced air cleaner media. Blower: 2.8A. Inducer: 2.17A. Suggestions: Run main system blower continuously for a couple days for humidity level to recover.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Blower: 5.4A. Inducer: 0.4A. Adjust Gas pressure: 3.6 inches water column. Was2.6. Temperature rise: 62 . Supply: 135 . Return: 73 . Paid by check #124 made out to HD.


John M.

John M. Job Checkin

Cleaned & checked condensing gas furnace. Checked drain. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Blower: 5.0A . Inducer: 0.27A . Gas pressure: 1.7 inches water column. Temperature rise: 45 . Supply: 119 . Return: 74 .


John M.

John M. Job Checkin

Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Checked filter. Compressor:9.0A . Condenser fan: 0.92A . Blower: 6.9A . ambient: 77 . liquid line: 82 . suction line: 40 . metering device: piston . Suction pressure: 118(40) . Return air: 69 . supply air: 49 .


John M.

John M. Job Checkin

Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Cleaned condenser coil. Checked filter: dirty. Customer plans to replace air filter media. Test capacitors: Found dual run capacitor weak: 26%low, fan side. Checked Freon level. Found system low on Freon and evaporator coil leaking. Compressor: 8.9A . Condenser fan: 0.78A . Blower: H. ambient: 88 . liquid line: 96 . suction line: 67 . metering device: TXV . Suction pressure: 116(39). Return air: 71 . supply air:56. Work suggested: replace warranty evaporator coil: $594. Replace warranty dual capacitor: $99. Vacuum air cleaner screen every month or two.


Roger H.

Roger H. Job Checkin

Replaced warranty evaporater coil


John M.

John M. Job Checkin

Found system low on Freon. Leak checked and found evaporator coil leaking. Need to replace coil. Also, condenser coil in need of cleaning. I charged system for temporary cooling. Work suggested: replace warranty evaporator coil: $594. Minus Freon credit: $234. Balance due $360.


Jeff K.

Jeff K. Job Checkin

NO COOL—found contactor NOT making good contact—added 1lb of r22


John M.

John M. Job Checkin

Work Done: Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Replaced air filter. Compressor: 7.8A.Condenser fan: .72A . Blower: 5.6A.ambient: 64 .liquid line: 65 .suction line: 50 .metering device: Piston . Suction pressure:60(34). SH: 16. T:10 . Return air: 66 .supply air: 45.5 .wet bulb: 53 .


Jeff K.

Jeff K. Job Checkin

Spring maintenance!


Roger H.

Roger H. Job Checkin

Serviced air conditioner system


Jeff K.

Jeff K. Job Checkin

Serv call...found bad ignitor...also shorted board out


Sean K.

Sean K. Job Checkin

Clean and check 2 systems


Roger H.

Roger H. Job Checkin

Adjusted water flow on humidifier


John M.

John M. Job Checkin

Customer stated that through the wall unit came on with the mode switch in the “stop“ position! The only thing thing that could cause this is a faulty Control board. An intermittent problem Billing credit card on file.