5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for gainesville, ga

Rated 4.8 out of 5 stars based on 185 customer reviews

Great Service

Jordan was knowledgeable and was able to answer my questions on the equipment and service needed. I was very satisfied with the job done.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great company

Very happy with service. Nice and polite. Will certainly call again.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Excellent

Christian came out late the night before the 4th of July Holiday, Fixed the problem quickly and efficiently and with a great attitude even after a long day. Great Service.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Quote

Good job

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Review

Excellent

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great job

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Outstanding service.

Chris was very courteous and knowledgeable, offering some helpful suggestions.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Good aervixe

Showed in a timely manner and completed al work in a same day.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service, Awesome Price

Upon scheduling this service, CSR was willing to work with me on the appointment time. Sorry I forgot her name. Jon called first and was here on time. Answered all my questions and explained what he found with visual aid on his phone. This service was followed up with a detailed report sent to my e-mail.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for gainesville, ga

Jordan R.

Jordan R. Job Checkin

No cool main level. Discovered system with frozen coil. Thawed coil out. Discovered system with weak compressor starter, weak secondary controller and low on charge. Performed leak search but could not find leak. Charged system back up to proper subcool and replaced weak components. System operation normal at this time


Jordan R.

Jordan R. Job Checkin

3 system cooling maintenance. Tested systems operation. All components tested within normal manufacturing spec. Upstairs system doesn’t not have drain line water safety installed to help prevent flooding in the case of common drain line clogs. All systems operation normal at this time


Jon F.

Jon F. Job Checkin

Completed diagnostic. Found system running good. Blower wheel is clean. Evap coil is clean with no rust or corrosion. All electrical connections are tight. No signs of drain clog. Temp difference in house is clean 19 degrees. With 53 degrees coming out of supply. Outside pressures are good and all electrical components are good with clean tight connections. System is cooling properly at this time. Informed customer that on days where outdoor temp is 95+ degrees the system will run much longer and may not get all the way down to temp just because of how hot it is.


Christian  S.

Christian S. Job Checkin

Arrived on site, found bad thermostat on main level. We installed unit back in 2017, replaced face under 5year labor 10year parts warranty. Will need to come back and put an new one on because the one I put on is dirty, but will work through weekend. System is running normally at this time


Jordan R.

Jordan R. Job Checkin

No cool. Discovered failed secondary controller. Replace controller and added compressor saver hard start kit to reduce stress on compressor and reduce energy consumption on start which will extend the life of the system.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jon F.

Jon F. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found drain line clogged. Cleared line. Replaced the thermostat that was not done during install. Turned system on to cooling. Everything working well. System draining condensate properly.


Jon F.

Jon F. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Upstairs has a clean blower and both forms of water safety. Replaced filter. Cleared drain line. Blower and coil are clean. The main floor missing back up water safety and no drain pan. Cleared drain line and added algae tablets to pump. Changed filter. Blower and coil are both clean. Washed off both outdoor units. Both pressures are good and all electrical components are good. Systems missing compressor saver and surge protection.


Mark S.

Mark S. Job Checkin

A/c repair call. On site, the client stated the system not cooling past 75 found low refrigerant charge. Checked for leak found a leak in the evaporator coil. After diagnosing leak went to adjust charge and condensing fan motor had gone out. Replaced fan motor under warranty adjusted charge. The system is now operating and cooling at this time. Need to schedule a comfort advisor to come out Wednesday, July 1st after 10 am.


Jon F.

Jon F. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found blower clean. Changed media filter. Cleared drain line. The electrical components in the furnace are good. The outdoor unit has great pressures. And working electrical components.


Jordan R.

Jordan R. Job Checkin

A/c repair call for the main system. Discovered faulty compressor saver hard start. Replaced. The system ran for 20 mins cycling on and off without issue. System operation normal at this time


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jon F.

Jon F. Job Checkin

A/c repair call. Found bad capacitor. Replaced capacitor. Blower wheel clean. Pressures are good contactor is slightly pitted. The system has no compressor saver or surge protection. Need to mail the invoice.


Christian  S.

Christian S. Job Checkin

Completed one system a/c repair call and preventative maintenance check. Arrived on site found condensation drain clogged. Cleared drain line and the system started draining properly. Checked pressures and systems. The unit is operating normally at this time. Clear condensation drain.


Christian  S.

Christian S. Job Checkin

Arrived on site to perform a one system maintenance. Indoor; checked the filter and cleared drain line. Checked electrical connections and amp draw. Found no water safety switch on the unit other than the condensation pump. Recommend installing an overflow switch in the evaporator coil. Outdoor; cleaned condenser coil and checked refrigerant pressures. Checked electrical connections, amp draw, and capacitance. The unit is operating at manufacturer specifications at this time. thank you for your business, we look forward to keeping you comfortable.