5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for lawrenceville, ga

Rated 4.9 out of 5 stars based on 97 customer reviews

Excellent Service!

Pleasant, knowledgeable and extremely competent. He knows his business. Excellent service, as we have always received from Comfort Control!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service!!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Excellent Service!

Very courteous, knowledgeable and Professional!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great!

Very happy with Reece! He did an exceptional job and explained everything to us so we could understand what was happening.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Ta is great! Courteous, knowledgeable, and thorough.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

checked everything out that was required

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

A positive experience. Will do business with him in the future for my 2 hvac systems.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

Reese is so friendly and knowledgeable

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Vu Tran

Always does a great job

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Company

Techs are knowledgeable, courteous and patient. They take the time to explain recommendations and answer questions.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for lawrenceville, ga

Steve I.

Steve I. Job Checkin

Completed 1 system furnace repair and preventative maintenance check. Found furnace running higher CO levels. Calibrated valve to bring levels to safe. Replaced the flame sensor and ignitor. System is running at safe levels.


Jon F.

Jon F. Job Checkin

Completed 2 system furnace repair and preventative maintenance check. Found both units to be very old and dirty. Recommended ductwork cleaning along with a blower and evaporator coil cleanings. Recommended combustion calibrations for both units. Recommended that the gas lines being brought up to code. Recommended blowing more insulation in the attic to be brought up to code. The customer declined all repairs. The systems are running at this time.


Vu T.

Vu T. Job Checkin

Completed 1 system furnace repair and preventative maintenance check. Find upstairs Goodman furnace 5 year old operating with in manufacturer spec. Find system have no water protection and drain pan damage. Find evaporator coil not level. Find furnace gas line not up to code. Find system missing return plenum and missing filter rack for filter. Give customer estimate to repair system. Find downstairs furnace 5 year old operating with in manufacturer spec. Find flue pipe not up to code, missing drain pan and water protection. Missing return box and filter rack. Give estimate to repair system. Both furnace operating at this time. Change filter for customer. Suggest Comfort Club membership plan and suggest duct cleaning. Suggest to capacitor off bathroom return vent.


Reece W.

Reece W. Job Checkin

Furnace repair call. Found control board reading pressure switch problem, found inducer motor going bad. The customer is replacing the system. Collected non-refundable deposit. The new system will come with 10 year part warranty and two years labor.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Ta K.

Ta K. Job Checkin

Furnace repair call for the upstairs system. Found system with bad pressure and ignition. Replaced both parts and system is now heating.


Vu T.

Vu T. Job Checkin

Completed 2 system furnace repair and preventative maintenance check. 1 year old operating within manufacturer spec. Find ac unit 16-year-old, operating with worn compressor and start-up stress, the contactor is worn and pitted, evaporator coil rusted and dirty plenums. Ac unit also a phase out R22 equipment by 2020. Find downstairs system furnace 16 years, operating within manufacturer spec, Dirty plenums. Find ac unit 1-year-old operating within manufacturer spec. Both system operating at this time. Suggest to upgrade upstairs ac unit. Suggest upgrade downstairs furnace. Suggest duct cleaning.


Reece W.

Reece W. Job Checkin

Found the secondary water safety unplugged. Plugged it back in and the system is heating at this time.


Ta K.

Ta K. Job Checkin

Completed 1 system furnace repair and preventative maintenance check. The air cleaner is good. Checked the electrical and safety switches. All are okay at this time. Found a worn ignition but it is still working at this time. The system is heating normally.


Steve I.

Steve I. Job Checkin

Completed 3 system furnace repair and preventative maintenance check. Replaced all of the filters. Added an inline float switch to the upstairs attic furnace. All of the furnaces are heating well at this time and at safe levels. The new downstairs heat-pump is working well. The customer is aware that the heat strip is not activated.


Tom K.

Tom K. Job Checkin

Furnace repair call. Replaced clogged drain tubing.


Ta K.

Ta K. Job Checkin

Came to give price for water heater. Water heater is the original of house. Around 17 years old. Found no expansion tank and rust underneath the water heater.


Ta K.

Ta K. Job Checkin

Completed 2 system furnace repair and preventative maintenance check. Air cleaner still ok. Checked electrical and safety switches all ok at this time. Did a combustion test and found high oxygen content on both furnaces. Did a combustion calibration on both systems to improve efficiency. Both system heating normally at this time.


Jon F.

Jon F. Job Checkin

Completed install of manual dampers to add air flow to bonus room.


Jon F.

Jon F. Job Checkin

Furnace repair call. Completed a diagnostic test and found that the control board was faulty. Need to get a new control board from the parts store and replace it.