5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for lawrenceville, ga

Rated 4.9 out of 5 stars based on 262 customer reviews

Great service

Vu Tran came to my residence and repaired my heating system. He took time to explain the issues to me. He’s the only one I want to take care of my heating needs.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Very informative

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Very Thorough

The service technician was very methodical in his assessment but also was sensitive to recommendations of a best cost solution

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Tankless water heater

Reece did not do any talking, just his manager. They told me that the scope of work was outside their abilities since they were primarily a heating and cooling company. The manager said that we mostly do remove and replace. I felt that they wasted my time. The manager as unfamiliar with the code requirements for the proximity of exhaust vent with relation to doors and windows.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Quality work

The technician, Christian, was thorough and personable as he explained the work that needed to be done, as well as providing information on upgrades that I could consider for my HVAC systems. This is my first time using this company and Christian provided the experience that I was hoping for.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

He explained everything in detail.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Good Service, Clear Communication

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great customer service. Was very helpful in helping me understand the thermostat and water heater

We had a problem with the pilot light going out. It is a holiday and the county was closed and couldn’t help us. With my elderly parent here, it was nice too have the heat back so we didn’t have to take cold showers. Thank you, great service’ I will recommend them and definitely use them again. 😊👍🏼

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

The person that came to my house is very polite respectful. He fix all the problem right away!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for lawrenceville, ga

Christian  S.

Christian S. Job Checkin

One system heat maintenance in Lawrenceville. Arrived on site changed media supplied by customer and cleared barometric pressure ports. Checked ignition systems, electrical connections, amp draw and capacitance. Recommended installing surge protector to protect electrical systems on each piece of equipment as well as a compressor assist kit to prolong the life of the system. Also quoted to install UV purifier to complete purification cycle in mitigating any mold, bacteria, viruses or air borne allergens in the air stream and in the evaporator coil. Unit is operating normally at this time


Christian  S.

Christian S. Job Checkin

One system heat maintenance in Lawrenceville, arrived on site checked filter and cleared drain line. Checked electrical connections, amp draw and capacitance. Found system with no secondary water safty switch and static pressure is on the high side, recommend installing overflow water safty switch and a PureAirX media to eleveate static pressure in the system. Also recommend installing surge protection to both pieces of equipment to protect electrical systems. Unit is operating normally at this time.


Vu T.

Vu T. Job Checkin

Sign 1 cci plan. Complete heating maintenance in Lawrenceville. Find system with fail flame sensor. Replace flame sensor. Check and find system overheating and over size for house and duct system. System operating with high static pressure. Complete combustion calibration to help reduce temperature to prevent overheating of furnace. Reduce air flow for system to help reduce high static pressure buildup. Customer will need additional return duct to help with airflow distribution. Give customer estimate to for additional duct. Per Jeff, remove flame sensor cost and replace with comfort control care club. Customer will have additional visit in Spring to check on AC UNIT. System operating at this time.


Reece W.

Reece W. Job Checkin

heat pump tune up in Lawrenceville, Georgia. One system. Did not change filter. Tested mechanical and electrical components. Found system low on r410a refrigerant. Performed a leak search and found leak in evaporator coil on right side. Recommend repair. Recommend surge protection to protect equipment from power surges. System is not heating properly at this time.


Jon F.

Jon F. Job Checkin

Heat tune up lawrenceville. Completed tune up on 5 year old furnace. System is running properly on arrival. Combustion and air flow are good. Blower wheel is slightly dirty. Evap coil is good. All heating and electrical components within range. Changed filter. Recommend maintenance plan as wel as secondary water safety device to protect furnace from water damage.


Garrett G.

Garrett G. Job Checkin

Free consultation Lawrenceville 30044


Jon F.

Jon F. Job Checkin

Heating tune up lawrenceville. Completed tune up. Master side system is 17 years old and heating decent now. Changed filter. Air flow is good. Combustion is good. Blower is very dirty. Evap coil rusted and corroded and running on r22 Freon. Recommend replacing system due to age and efficiency. Right side system 11 years old. Clean blower and coil. Changed filter. Combustion and air flow is good. Missing secondary water safety device on both systems. Missing indoor air quality systems in both. Insulation in attic is very low and needs more blown in.


Christian  S.

Christian S. Job Checkin

One system tune up in Lawrenceville. Arrived on site, found unit inoperable due to bad ignitor. Customer had a power outage and after the unit wouldn't come back on. Also found a degraded aux drain pan and no water safty, units gas line not up to code with flex line run directly into the gas valve, flue pipe is improperly ran coming out of furnace and and then at a downward angle this unable to properly vent combustible gasses. Blower motor assembly is dirty and motor has a weak capacitor. Evaporator coil is R22, corroded and needs to be cleaned. At this time due to age and condition of system I recommend replacing equipment, plenums and re running flue pipe. Will need to send a consultant out for a quote. Unit is not operational at this time. Turned power to unit off at furnace switch.


Christian  S.

Christian S. Job Checkin

No heat in Lawrenceville, arrived on site, found system running. Found static pressure across filter abnormally high, replaced with filter to slow better air flow. Found system without water safty at all. Recommended installing due to code as well as water damage prevention. Found improperly ran gas line with no drip-t, needs to be addressed per code as well as to prevent gas valve from clogging. Recommended installing air purifier to improve indoor air quality as well as electrostatic media to improve air flow. Also found warn ignitor that may be failing causing unit to go into lockout because it would be in able to light hot gasses. Replaced ignitor and filter for customer. Unit is operating normally at this time.


Christian  S.

Christian S. Job Checkin

One system heat maintenance in Lawrenceville, arrived on site changed filter and cleared barometric pressure ports. , checked ignition systems, electrical connections, amp draw and capacitance found clogged filter causing air obstruction. Recommended installing air purifier to improve indoor air quality inside house unit is operating normally at this time.


Christian  S.

Christian S. Job Checkin

One system tune up in Lawrenceville. Arrived on site, changed filter and cleared barometric port. Checked ignition systems, electrical connections, amp draw and capacitance. Found upstairs system with warn flame sensor, a blower capacitor reading low, only one form of water safty, corroded evaporator coil, a duel run capacitor reading low in the outdoor unit as well as a burnt and pitted contactor. Recommended installing surge protector to each piece of equipment, replacing capacitors pulling and cleaning dirty blower assembly and evaporator coil as well as installing a disconnect box for the outdoor unit. At this time, the system is operating, but amp draw is high on all motors as well as many warn parts. Recommend replacing equipment due to age and condition of system.


Christian  S.

Christian S. Job Checkin

One system heat tune-up in Lawrenceville. Arrived on site, changed filter and cleared barometric ports, checked ignition systems, electrical connections, amp draw and capacitance. Found dirty blower assembly and a warn flame sensor. Recommended pulling and cleaning the blower motor assembly and replacing flame sensor. Also found that the duel run capacitor in the outdoor unit is still within spec, but it is on the lower end of good and should be replaced in near future to reduce any stress being put on compressor. Recommended installing surge protection to both pieces of equipment, as well as a compressor assist kit to the outdoor unit


Christian  S.

Christian S. Job Checkin

One system heat maintenance in Lawrenceville. Arrived on site, changed filter and cleared barometric ports, checked ignition systems, electrical connections, amp draw and capacitance. Found newer system from 2018, found no issues with the system other than a dirty filter. Recommended installing an air purifier to improve indoor air quality as well as keep the equipment free from any organic growth inside the unit. System is operating normally at this time.


Christian  S.

Christian S. Job Checkin

3 system tune up in Lawrenceville. Arrived on site, changed filter and cleared barometric ports. Checked ignition systems, electrical connections, amp draw and capacitance. Main level, found warn ignitor, dirty blower assembly, and corroded evaporator coil, system also only has one form of water safty. Basement unit is old as the main level with no water safty, dirty blower assembly and corroded evaporator coil. Recommended installing surge protection to all equipment as well as compressor assist kit for upstairs system. Units are operating normally, however I recommend replacing equipment for main and basement systems due to age and condition of equipment.


Garrett G.

Garrett G. Job Checkin

Free consultation for new water heater