Routine Cleaning

David was extremely helpful and he kept me informed the entire time.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Quick and professional

Jon was very nice and I was very glad the only problem was a dirty unit. Thank you and I will use you again!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great professional service and took the time to explain the problem

My experience with Jon was just wonderful. Well mannered service man.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Experience

Good Job, quick diagnosis.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Well Done

Thanks for getting to us so promptly, Jordan did a great job!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

Very professional and courteous technician

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for lawrenceville, ga

Reece W.

Reece W. Job Checkin

Drain line had slight upward tilt. Cut out section of line, re did it and drain line is downward and draining at this time. Recommend secondary water safety


Steve I.

Steve I. Job Checkin

Found compressor wire on the motor controller burnt. Sign that the system is over amping. Replaced motor controller and fixed wire connection. Added a start kit to condenser for easier start up.


David D.

David D. Job Checkin

Fix Deferred Revenue for Accounting


Reece W.

Reece W. Job Checkin

Fix Deferred Revenue for Accounting


David D.

David D. Job Checkin

Accounting Fix for Deferred Revenue


Vu T.

Vu T. Job Checkin

No cool again. Find heatpump capacitor bad. Replace capacitor and system operating again. Test and system operating with stress and worn compressor and fan motor. Told customer if system fail again in the next 30 day will refund the cost of capacitor. Suggest to upgrade system. Give customer estimate to to upstairs system


Steve I.

Steve I. Job Checkin

Found system completely down. Checked inside furnace and was getting voltage to board. Voltage was only 109-110. Found the room directly next to furnace with no power. Electrical lines look to share same circuit. Recommend getting electrician out to check lines.


Jon F.

Jon F. Job Checkin

Correct deferred revenue for Accounting


Ta K.

Ta K. Job Checkin

2 system ac renewal. Replaced air cleaner provided by owner. Cleared drain and clean both condenser coil. Both system cooling normal


Ta K.

Ta K. Job Checkin

Install 3 Ton 14 seer cooling system. Test and system operating at this time.


Vu T.

Vu T. Job Checkin

Warranty service call. System not cooling properly. Adjust fan speed and clear clogged drain line. System cooling at this time. Customer said system can not go below 77 degrees during the day.


Reece W.

Reece W. Job Checkin

One system tune up/ no cool. Left replacement filter. Found system not cooling due to low r22. Found rusted evaporater coil. Found weak capacitor and blower capacitor. Found burnt main electrical switch. Chemically washed condenser coil. Due to age and condition of system, recommend upgrading system to a more reliable, more efficient system. Customer just wants to recharge with sealer for now and replace bad electrical components. Explained to customer that r22 is being phased out in 2020 and that leak seal is not guaranteed and may not be successful. Recharged system with 4 lbs r22, replaced capacitor and blower capacitor and replaced main electrical switch. System is cooling at this time. Customer upgraded tune up to maintenance plan


Tom K.

Tom K. Job Checkin

Installed mini split


Vu T.

Vu T. Job Checkin

No cool. Check and find upstairs system have bad starter and low charge. Recharge system and install hard start kit. System operating at this time. Change filter. Find mini split system drain was clogged, remove clogged and recharge system to manufacturer spec. Both system operating at this time.


Steve I.

Steve I. Job Checkin

COmpleted 2 system cooling maintenance. Replaced filters provided by the customer. Added inline safety switches to both attic Airhandler and Furnace. Added start kits to both Condensers. Systems are cooling good at this time.