David was courteous and explained everything he did before he did it. He wore special shoes in the house and even played with my dogs! He also made reasonable recommendations that didn't seem like he was just trying to get money from you. He also really tries to work around your schedule and is very punctual.
Air conditioner service call. AC not cooling. Found a bad fan motor.
Maintenance agreement air-conditioning tuneup for a Trane air conditioner. The amp draws are good both capacitors are within manufacture specs refrigerant levels are right where they should be chemically cleaned the washable air filter and the outdoor coil this air-conditioner is ready for summer
Perform a no heat service call on a York 90+ furnace found a bad pressure switch replaced pressure switch furnace is working and heating upon repairs
Performed a furnace and air conditioner inspection on comfort maker equipment found bad run capacitors and air-conditioner low on refrigerant performed leak search and found evaporator coil leaking provide a quotefor repairs and replacement
Sunday no he service call on a carrier furnace found the inducer had a bad electrical wiring replaced inducer assembly unit is heating well now
Performed a bonus check on a carrier furnace found a bad blower capacitor and leaking gas valve repaired furnace unit working well now
Performed a furnace tuneup on a comfort maker furnace unit checks out good
Perform tuneup on York furnace found a bad hot surface igniter replaced igniter and cycled system furnace is he eating well
Performed a furnace tune up on an American Standard furnace. Unit checks out good and ready for winter
Installed new Comfortmaker furnace set system up unit heating well
Quoted new Comfortmaker 92% efficient furnace
No cooling service call on a Trane system. Found bad dual run capacitor. Replaced cap and checked system. Compressor pulling high amps with low pressures. Recommend replacing unit as compressor has lost capacity. Quoted new Comfortmaker air conditioner.
Emergency no cooling call on a trane system found a bad dual run capacitor or replaced in system is running