Job Checkin

Customer had very low water pressure and could hear a “siphoning” sound when she opened the hot side. I went into the crawl space and could confirm there was a water leak where the water line turned up into the kitchen sink cabinet. After cutting the pipe, I saw that the previous plastic shark bite had been broken. This is most likely because of it being installed against the floor board. In order to prevent abrasion in the future, I used a 90 so the new pipe goes straight up through the floor. I used shark bites to attach the pex in the crawl and under the sink. Once installed, I turned the water back on and relieved the air out of the kitchen sink line. Did a full inspection of installed pipe and no water leaks could be detected. Customer stated that the water pressure was much better than it had been. Told the customer she could turn the water heater back on. Customer had shut off the heater previously. Thank you for choosing CPI!