They turned the breaker back on and the control box with the capacitor was making a bad clicking sound. I pulled the panel open and using a multimeter i tested the capitol and it was not reading the ohms like it was suppose to. Double checked the incoming power and the pressure switch all checks out. I believe it is the control panel that need the capacitor replaced. Pump company Dahlman well and pump 360-757-6666