6660 Dixie Hwy Suite 302
Fairfield, OH 45014
5135401716

Local Reviews
for fairfield, oh

Rated 4.7 out of 5 stars based on 6 customer reviews

Great service, awesome price!

Shawn (sp?) was courteous and knowledgeable. Impressed with his service. Will definitely consider your company for future service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Furnace Repair /Maintenance

Arrived quickly, polite, courteous, knowledgeable. Thank you Josh.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Happy I chose them!

I found this company on a google search, which made me a little nervous, but it turned out to be a really good choice. The technician was confident without being cocky and a super nice guy. I felt like things were in good hands. My furnace was 20 yrs old and he recommended a new one, but didn’t push at all. I really appreciated that. He explained what was wrong very thoroughly and gave me a precise estimate.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

Your uniformed tech Hassan inspected and diagnosed my furnace and heat pump,he was thorough Knowledgeable and professional if we ever need HVAC work done again you will be my first call.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Josh came out to diagnose the problem, and they will order the part on Monday! I will let you know more after the job is complete! But everything was explained to me so I understood exactly what I was dealing with along with pricing!

  • Overall Experience
  • Quality
  • Price
  • Convenience

T

My service techinician was very helpful and kind

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for fairfield, oh

Courtney H.

Courtney H. Job Checkin

I completed a diagnostic service call on a Bryant Air conditioner. Determined that there were no issues.

I completed a diagnostic service call on a Bryant Air conditioner. Determined that there were no issues.

Ibrahima D.

Ibrahima D. Job Checkin

I completed the spring tune up on a Rheem air conditioner. I visually inspected the furnace. Checked voltage and amps. I inspected the evaporator coil. I checked the temperature difference across the coil. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored the system. Operating normally at this time.

I completed the spring tune up on a Rheem air conditioner.  I visually inspected the furnace.  Checked voltage and amps. I inspected the evaporator coil.  I checked the temperature difference across the coil.   Checked refrigerant charge, voltages and amps.  I rinsed the condenser coils with water.  Cycled and monitored the system.  Operating normally at this time.

Gage R.

Gage R. Job Checkin

I removed a Tempstar Gas Furnace and Carrier Air Conditioner. I installed a Five Star 96% 80,000 BTU Gas Furnace and a 16 SEER 2.5 Ton Air Conditioner. Cycled and monitored the system. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.

I removed a Tempstar Gas Furnace and Carrier Air Conditioner.  I installed a Five Star 96% 80,000 BTU Gas Furnace and a 16 SEER 2.5 Ton Air Conditioner.  Cycled and monitored the system.  Operating normally at this time.  Included with the installation is a free 1 year service maintenance agreement.

Gage R.

Gage R. Job Checkin

I completed an install of a Carrier Variable Speed 3 Ton Electric Furnace/ "Slant" Coil, a Carrier 16 SEER 3 Ton Heat Pump, and an Aprilaire 600M Humidifier.

I completed an install of a Carrier Variable Speed 3 Ton Electric Furnace/ "Slant" Coil, a Carrier 16 SEER 3 Ton Heat Pump, and an Aprilaire 600M Humidifier.

Gage R.

Gage R. Job Checkin

I installed a Five Star 80% 70,000 BTU Gas Furnace 3T 17" to replace the customer's current unit. I cycled the system to ensure functionality. System is operational upon departure.

I installed a Five Star 80% 70,000 BTU Gas Furnace 3T 17" to replace the customer's current unit. I cycled the system to ensure functionality. System is operational upon departure.

Gage R.

Gage R. Job Checkin

I installed a Five Star Multi-Speed 2 Ton Electric Furnace.

I installed a Five Star Multi-Speed 2 Ton Electric Furnace.

Bella  M.

Bella M. Job Checkin

I found that the system would run briefly then inducer would fill up with water and shut down. I cleared clog in drain line running from bottom of flue to condensate trap. I restarted system and it is now operational and heating the house.

I found that the system would run briefly then inducer would fill up with water and shut down. I cleared clog in drain line running from bottom of flue to condensate trap. I restarted system and it is now operational and heating the house.

Tara L.

Tara L. Job Checkin

I found that the thermostat is bad so I replaced with a Honeywell6 programmable thermostat. I also found that one of the heat banks will need replaced as client has been using emergency heat to heat the house. I recommend replacing the 1987 Carrier electric furnace, client will let me know.

I found that the thermostat is bad so I replaced with a Honeywell6 programmable thermostat. I also found that one of the heat banks will need replaced as client has been using emergency heat to heat the house. I recommend replacing the 1987 Carrier electric furnace, client will let me know.

Bella  M.

Bella M. Job Checkin

I found that loss of power was due to the blower cabinet door coming loose and triggering door switch safety so I secured door and restarted system. I noticed flame rollout on startup and found multiple cracks and heat exchanger. Customer has opted to replace Bryant gas furnace.

I found that loss of power was due to the blower cabinet door coming loose and triggering door switch safety so I secured door and restarted system. I noticed flame rollout on startup and found multiple cracks and heat exchanger. Customer has opted to replace Bryant gas furnace.

Mary C.

Mary C. Job Checkin

I found that the wiring on indoor and outdoor Rheem unit do not correspond with each other and unit also needs to be rewired. Customer has home warranty and will go through them for repairs.

I found that the wiring on indoor and outdoor Rheem unit do not correspond with each other and unit also needs to be rewired. Customer has home warranty and will go through them for repairs.

Mary C.

Mary C. Job Checkin

I checked defrost board on outdoor unit and forced system into test mode, however system would not stay in a defrost cycle. Will schedule a time to come out and replace OEM defrost sensor.

I checked defrost board on outdoor unit and forced system into test mode, however system would not stay in a defrost cycle. Will schedule a time to come out and replace OEM defrost sensor.

Bella  M.

Bella M. Job Checkin

I found that the thermostat wasn't sending voltage to the control board. I replaced customer thermostat with an Emerson programmable thermostat and cycled system to verify it worked. System is on at time of departure.


Bella  M.

Bella M. Job Checkin

I replaced the humidifier solenoid and verified that there are no leaks. Humidifier is operational at this time.

I replaced the humidifier solenoid and verified that there are no leaks. Humidifier is operational at this time.

Bella  M.

Bella M. Job Checkin

I found the humidifier stopped working because the solenoid failed. I verified by checking to make sure 24 volts were going to it. Saddle valve leaks when it is adjusted needs to be replaced. Everything else was performing within manufacturers specifications system is on and operational at time of departure

I found the humidifier stopped working because the solenoid failed. I verified by checking to make sure 24 volts were going to it. Saddle valve leaks when it is adjusted needs to be replaced. Everything else was performing within manufacturers specifications system is on and operational at time of departure

Gage R.

Gage R. Job Checkin

I installed a Carrier Multi-Speed X-13 3 Ton Electric Furnace and a Carrier 14 SEER 3 Ton Heat Pump. With this install comes a scheduled maintenance agreement lasting a year.

I installed a Carrier Multi-Speed X-13 3 Ton Electric Furnace and a Carrier 14 SEER 3 Ton Heat Pump. With this install comes a scheduled maintenance agreement lasting a year.