100-A Brownstone Rd
Oakley, CA 94561
925-625-4963

Our Top Cities


Local Reviews

Rated 4.9 out of 5 stars based on 281 customer reviews

Excellent service and always professional


Response from Fairview Heating & Air Conditioning:

We are so grateful for your kind words.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Semiannual Service experience

Very happy with the service received. Appointment was easy to schedule and the service rep. was on time, friendly and respeectful. I have used Fairview previously and have been very satisfied.


Response from Fairview Heating & Air Conditioning:

It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Jerry did a great job,and a really nice man. As always, Fairview can be relied upon for excellent service!


Response from Fairview Heating & Air Conditioning:

We are so grateful for your kind words.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Fairview Heating & Air Conditioning:

Thanks for sharing your review with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service Call

Jerry came on time, replaced filters, checked A/C unit said the could go as it is but there was an original contact was showing signs of wear. He shared what the problem was, and why it would be good to replace, told him to go ahead, and he replaced it quickly. Highly recommend him and Fairview Heating.


Response from Fairview Heating & Air Conditioning:

We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service very efficient

All service performed well into my satisfaction


Response from Fairview Heating & Air Conditioning:

We are so grateful for your kind words.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good

I was not there when he serviced but my wife said he checked the furnace, and air conditioner and cleaned the A/C condenser coils and changed the filters 👍


Response from Fairview Heating & Air Conditioning:

Thanks for sharing your review with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Maintenance Service

The service rep was on time and courteous. Our ac/heating unit has been on a six months maintenance program with Fairview Heating and Air for quite a while and we are grateful for the knowledgeable service staff.


Response from Fairview Heating & Air Conditioning:

We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service.

Jerry was very informative & Cordial. I will be calling for an appointment soon to find the freon leak. Thank you for your service.


Response from Fairview Heating & Air Conditioning:

It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service👍😀

I called the customer service and able to get an appointment on the same day to check my air conditioner because it was not turning on. Grant P. came on time. He checked the air conditioner at backyard and went up to the attic to check the furnace. He was able to fix the problem right away and explained to me the problem. He's very professional, friendly, and easy to talk to. Excellent service👍😀.


Response from Fairview Heating & Air Conditioning:

We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent, fast service. Highly recommend.

Air conditioning was not working. He came in the same day, diagnosed the electrical problem. Fixed it . Excellent, fast service. Highly recommend.


Response from Fairview Heating & Air Conditioning:

Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Consistent Service

I appreciate the consistent high quality service from Jerry. I will always request him as my technician


Response from Fairview Heating & Air Conditioning:

We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Jerry was very thorough with the service of our air conditioner. He was need and made sure he wore his feet covers when he was in the house. He answered any questions we had. Very knowledgeable.


Response from Fairview Heating & Air Conditioning:

Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Jerry was very efficient and courteous. You guys are the best.


Response from Fairview Heating & Air Conditioning:

We are pleased to know your experience with us was a good one!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual Pre-season Air Conditioning Maintenance

Jerry always does a great job to keep me informed of problems if any and to fix them. He is very pleasant and does the job well.


Response from Fairview Heating & Air Conditioning:

Thank you for sharing your kind words with us. It means the world to us and to our entire team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Barbara C.

Barbara C. Job Checkin

Responded to a no-cooling issue and unusual noises from a Lennox XC21 outdoor unit in Brentwood, CA. Upon inspection, identified a defective fan motor as the source of the noise. Replaced the fan motor and capacitor with Lennox-approved parts. Verified refrigerant levels and cleaned the condenser coils. Secured all electrical connections and performed a system test to ensure proper cooling and noise resolution. Regular maintenance is essential for preventing such problems and maintaining efficiency.


Barbara C.

Barbara C. Job Checkin

Conducted annual maintenance on dual-system Lennox XC25 air conditioners in Antioch, CA residence. Performed comprehensive inspection and tune-up on both units. Cleaned condenser coils using low-pressure wash and coil brightener. Checked and tightened all electrical connections, measuring voltage and amperage draw. Lubricated fan motors and inspected belts for wear. Calibrated thermostats and tested safety controls. Cleaned condensate drain lines and treated with algaecide. Verified refrigerant charge using subcooling method. Both systems operating at optimal efficiency, ensuring reliable cooling performance for Antioch's hot summer climate.


Jessica S.

Jessica S. Job Checkin

Performed comprehensive duct cleaning and system optimization on Trane XR16 heat pump system. Utilized negative air pressure machine with HEPA filtration to remove debris from supply and return ducts. Inspected ductwork for leaks using smoke pencil test, sealing identified leaks with mastic sealant. Cleaned evaporator coil with biodegradable foaming cleaner. Sanitized system with EPA-registered disinfectant. Adjusted dampers for balanced airflow. Replaced air filter with MERV 13 media. Verified proper static pressure and refrigerant charge. System now operating at peak efficiency with improved indoor air quality and reduced energy consumption.


Robert C.

Robert C. Job Checkin

Resolved an issue with an AC unit that would not turn on. Conducted a thorough diagnostic, starting with testing the thermostat for proper settings and functionality. Checked for tripped circuit breakers and verified voltage at the contactor. Found and replaced a faulty contactor. Inspected and tightened all electrical connections. Tested the system to confirm reliable operation. Regular AC maintenance can prevent unexpected breakdowns and ensure efficient performance.


Keanu I.

Keanu I. Job Checkin

Executed replacement of dual run capacitor on Carrier 24ABC6 central air conditioning unit. Diagnosed 45/5 μF capacitor failure using Fluke 902 FC HVAC clamp meter. Safely discharged existing capacitor before removal. Installed new OEM-equivalent GE Genteq C4455R capacitor, ensuring proper microfarad rating and voltage match. Verified secure fastening and correct wiring to compressor and fan terminals. Conducted amperage draw test on both motors, confirming improved performance. Checked system pressures and subcooling to ensure optimal operation. Unit now functioning at peak efficiency with restored cooling capacity.


Grant  P.

Grant P. Job Checkin

Repaired an AC system with wiring damage caused by rodents. Replaced all compromised wires with new, high-quality insulated conductors. Inspected the entire electrical system for additional damage and ensured proper connections. Tested the unit to verify safe and efficient operation. Proper wiring maintenance is crucial for preventing electrical hazards and ensuring reliable AC performance.


Jerry S.

Jerry S. Job Checkin

Investigated residential AC unit emitting unusual odor. Conducted thorough inspection of system components. Discovered significant microbial growth on evaporator coil, causing "dirty sock syndrome." Performed deep cleaning of coil using self-rinsing, alkaline-based cleaner. Applied EPA-registered biocide treatment to prevent future growth. Cleaned condensate drain line and installed P-trap to maintain proper drainage. Replaced contaminated air filter with MERV 11 pleated filter. Verified proper refrigerant charge and airflow. System now operating efficiently with improved indoor air quality and elimination of offensive odor.


Jerry S.

Jerry S. Job Checkin

Responded to warranty service call for residential HVAC system. Diagnosed R410A split system exhibiting insufficient cooling. Performed comprehensive inspection, including static pressure test and refrigerant charge verification. Identified faulty thermostatic expansion valve (TXV) causing improper refrigerant flow. Replaced TXV under manufacturer's warranty, ensuring proper superheat settings. Conducted system evacuation to 500 microns before recharging. Verified correct operation with 20°F delta T across evaporator coil. Cleaned condensate drain line and treated with algaecide. System now operating at peak efficiency, restoring home comfort. All work completed within warranty terms at no cost to homeowner.


Keanu I.

Keanu I. Job Checkin

Completed an AC repair service to restore optimal performance. Diagnosed and replaced a faulty capacitor, which was causing startup issues. Cleaned and inspected the evaporator and condenser coils to ensure efficient heat transfer. Checked refrigerant levels and recharged as necessary. Tightened electrical connections and tested the system for proper operation. Professional AC repair ensures reliable cooling and energy efficiency.


Grant  P.

Grant P. Job Checkin

Executed comprehensive AC system diagnostics and repair. Identified faulty dual-run capacitor (35/5 μF) using capacitance meter. Replaced with OEM-equivalent component. Conducted amperage draw test on compressor and fan motors. Assessed refrigerant charge using superheat and subcooling methods. Cleaned condenser coils with biodegradable degreaser. Calibrated thermostat and verified proper cycling. System now operating at optimal efficiency, restoring comfort and reducing energy consumption.


Jessica S.

Jessica S. Job Checkin

Conducted thorough AC maintenance and cleanup. Cleaned evaporator and condenser coils to improve efficiency. Checked refrigerant levels and ensured proper airflow. Inspected and tightened electrical connections, lubricated moving parts, and replaced air filters. Verified thermostat accuracy and tested the system for optimal performance. Regular AC maintenance boosts efficiency, extends equipment life, and ensures reliable cooling.


Jerry S.

Jerry S. Job Checkin

Implemented advanced air purification system: whole-house UV air cleaner installation. Integrated UV-C germicidal lamp (254 nm wavelength) into existing HVAC ductwork. Installed 24V transformer for power supply. Mounted lamp perpendicular to airflow for maximum microbial exposure. Ensured proper safety interlocks and indicator lights. System designed to neutralize airborne pathogens, including bacteria, viruses, and mold spores. Improves indoor air quality by reducing biological contaminants throughout the home.


Jessica S.

Jessica S. Job Checkin

Completed the replacement of an American Standard Silver 16 AC unit. Safely disconnected and removed the existing unit. Installed the new condenser and air handler, ensuring proper alignment and secure mounting. Connected the refrigerant lines using flare fittings, and brazed the joints for a leak-proof seal. Wired the electrical connections, adhering to NEC standards. Recharged the system with R-410A refrigerant to the specified levels. Calibrated the thermostat and checked system pressures, superheat, and subcooling values. Conducted a thorough performance test to ensure optimal cooling efficiency. Confirmed the unit is operating reliably and meets all manufacturer specifications for performance and energy efficiency.


Grant  P.

Grant P. Job Checkin

Replaced an American Standard Silver 14 AC unit. Disconnected and removed the old unit, ensuring safe disposal according to EPA guidelines. Installed the new condenser and air handler, verifying proper placement and secure mounting. Connected the refrigerant lines, electrical wiring, and drain line, ensuring all connections were airtight and secure. Charged the system with R-410A refrigerant to the manufacturer’s specifications. Calibrated the thermostat and checked system pressures, superheat, and subcooling values. Tested the unit for efficient cooling performance and verified all components functioned correctly, ensuring reliable operation and improved energy efficiency for the homeowner.


Keanu I.

Keanu I. Job Checkin

Repaired a Carrier Infinity AC unit that was not cooling. Diagnosed a refrigerant leak in the evaporator coil and a faulty capacitor. Repaired the leak, recharged the system with R-410A refrigerant, and replaced the capacitor. Verified system pressures and tested for proper cooling performance. The unit is now operating efficiently.