The technician arrived to tune up our unit. He was on time,very precise and knowledgeable. Whatever questions I had, he answered to my satisfaction.Your office represent Mr. Lundy and field representative, Mr. Garner are great assets to your company.
Furnace had a blown fuse, replaced fuse and system is functioning properly upon departure.
I arrived for a maintenance tune up. I made sure everything was working property. Change out filter.
I arrived for a maintenance tune up. Customer says it was a loud sound coming from his outside system yesterday but today it stop. I cleaned everything an made sure everything was working properly. There were no sound coming from the system when I was there.
Found system running in heat due to reversing valve wire not plugged up on control board on indoor unit. Corrected wiring issue and system came on in cool. System functioning properly upon departure.
Arrived on call system not cooling properly, customer said she called in for tuneup and hasn’t used cooling yet. Cycled system at thermostat checked all components wiring, refrigerant, amps, motor controllers, temp split, and cleaned outdoor coils and drains. Amana gas package unit 3.0ton 6 years old Compressor rla 14.10=11.43 Outdoor fan fla 1.50=1.24 Blower fla 3.90=2.89 Inducer motor fla 1.40=1.11 Outdoor temp 75 Suction psi 130 Liquid psi 300 Supply temp 57 Return temp 76 Capacitor 45/5=45/5 Did not find any issues at this time system working as should.
These are the items needed to ensure the proper operation and comfort of your home.
Arrived to find ductwork torn up and losing all airflow in the attic. Customer decided to get it all replaced for $3,235. We are awaiting approval through Alabama power and will schedule once we get approval.
Performed system clean and check Replaced 313 media filter. No other areas of concern. System operating properly upon departure.
Arrived for di and thermostat was off she said her nephew changed out dryer yesterday. Reser breaker and thermostat came on but was on lock. Her nephew is getting thermostat and is putting on himself.
Wire was off limit switch.system works as it should, customer paid with check.69.00
Bad draft motor and heavy rust on heat exchanger. Customer friends showed up during service call said he could get. Unit for them.
Arrived to 2x 39$ furnace tune up upon inspection found 2 gas package units that we installed not to long ago found both flame sensors dirty on unit closest to the garage 1 burner wasn’t lighting up causing it to cycle gas clocked burner and it lit up all units are safe for operation blowers are clean and filters changed regularly gas pressures are correct as well both systems heating upon departure Customers are talking about 2x maintenance plans at 149 each there 78$ will be taken off so all they would owe is 220