Checked system found one of the supply duct off. Also has two whole in the return duct. Customer said her son in law had repaired the other unit it is on at this time. Customer need to get duct work repaired.
Performed silver ESA summer maintenance. Checked amp draws on motors and compressor. Checked coil. Checked temperature split, refrigerant pressures. Checked water and water temperature. Informed customer they need new 20x25x4 media filter. Unit is operating properly at this time.
Installed new thermostat and outdoor sensor. Checked system. Checked duct work. Checked temperature split, refrigerant pressures. Amp draws on motors and compressor. Checked water flow and temperature. Informed customer they need new 20x25x4 media filter. Unit is operating properly at this time.
Checked system. Found contactor had replaced contactor. Also had to add a Hard Start. System working fine at this time. 3 1/2 ton Heil system model # 2H342AKB100 SERIAL# E070825452
ORHP 6217-7596, Check system. Found customer has a electrical problem on there breaker need a electrician to come out.
Checked thermostat and changed it to nonprogramable. I informed customer if he wanted to replace Tstat it is under warranty but we will charge 125.00 per hour to replace. He is gonna wait and see if I fixed problem.
Looks like a cat ruined at least 2 runs, rest looks like it’s old and needs replaced
Preformed gold winter maintenance on a Trane split heat pump HVAC unit (downstairs), unit is functioning properly at this time
Preformed a gold winter maintenance on a Trane split heat pump HVAC unit (upstairs), unit is functioning properly at this time
Changed blower motor under warranty, unit is functioning properly at this time
Preformed winter maintenance on a Bosch geothermal split heat pump HVAC unit, found a weak capacitor, changed it under P&L warranty.