7243 Sawmill Rd, Ste 205B
Dublin, OH 43016
(614) 490-7520

Local Reviews
for reynoldsburg, oh

Rated 4.8 out of 5 stars based on 4 customer reviews

Fast turn around for installation

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service call.

Thanks for the quick replacement of our furnace igniter. Great service and communication, as usual.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent maintenance visit

As usual, Pickerington Heating and Cooling did a great job with our maintenance visit today. Very professional and thorough. Great communication from the office and the technician. Thanks!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Furnace issues

My furnace had issues the day before Thanksgiving, I was able to get an appointment that day and Mike showed up promptly and found the issue. Unfortunately we are still waiting for a part but overall pleased with the service received.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for reynoldsburg, oh

Lucas M.

Lucas M. Job Checkin

Upon arrival I completed a Full Install of a Carrier 96% Gas Furnace Up to 100,000 BTU Carrier 13 SEER Air Conditioner System (Add $500 to upgrade to16 SEER) Up to 3 Ton. The system is operational upon departure.

Upon arrival I completed a Full Install of a Carrier 96% Gas Furnace
Up to 100,000 BTU Carrier 13 SEER Air Conditioner System
(Add $500 to upgrade to16 SEER) Up to 3 Ton. The system is operational upon departure.

Lucas M.

Lucas M. Job Checkin

Upon arrival I completed Half Install of a Annual Spring Air Conditioner Sale Carrier 16 SEER Air Conditioner System Complete 24ABC6 (Up to 3 Ton) The system is operational upon departure.


Lucas M.

Lucas M. Job Checkin

I competed a Half Install of a Annual Spring Air Conditioner Sale Carrier 13 SEER Air Conditioner System Complete 24ABB3 (Up to 3 Ton). The system is operational upon departure.


Adam  S.

Adam S. Job Checkin

I completed the Half Install of a Carrier 13 SEER 3.5 Ton Air Conditioner. The system is operational upon departure.


Jason A.

Jason A. Job Checkin

I completed diagnostics on the 14 yr old Atlas Butler AC unit. I determined the AC system was out of refrigerant. Customer doesn't want to move forward with repairs at this time. Five Star 80% 45,000 BTU Gas Furnace 3T 17"


Haidar H.

Haidar H. Job Checkin

I completed a diagnostic on a Gas Furnace. I determined that the circuit board has some burn marks on it as well as rust causing the fan to stay on 24/7 without a call for G. I presented the customer with repair and replacement options.


Lucas M.

Lucas M. Job Checkin

I removed a Goodman Air Conditioner. I installed a Five Star 13 SEER 2.5 Ton Air Conditioner. Cycled and monitored the system. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.


Jason A.

Jason A. Job Checkin

I completed the scheduled maintenance agreement cooling tune up on a Carrier air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.

I completed the scheduled maintenance agreement cooling tune up on a Carrier air conditioner.  I visually inspected the unit.  Checked voltages, amps and pressures. I inspected the evaporator coil.  I checked the temperature difference across the coil.  Inspected heat pump.  Checked refrigerant charge, voltages and amps.  I rinsed the condenser coils with water.  Cycled and monitored system.  All operating normally at this time.

Lucas M.

Lucas M. Job Checkin

I installed a Five Star 80% 45,000 BTU Gas Furnace 3T 17" and a Five Star 13 SEER 2.5 Ton Air Conditioner. System is set and customer is ready for the cooling season.

I installed a Five Star 80% 45,000 BTU Gas Furnace 3T 17" and a Five Star 13 SEER 2.5 Ton Air Conditioner. System is set and customer is ready for the cooling season.

Jason A.

Jason A. Job Checkin

I completed a scheduled maintenance agreement for a heat pump. Customer stated back up heat in air handler was not coming on automatically, have to switch to emergency heat manually. Check thermostat, thermostat is bad.

I completed a scheduled maintenance agreement for a heat pump. Customer stated back up heat in air handler was not coming on automatically, have to switch to emergency heat manually. Check thermostat, thermostat is bad.

Adam  S.

Adam S. Job Checkin

I installed a Carrier 13 SEER 3.5 Ton Air Conditioner. System is set and ready for the cooling season.

I installed a Carrier 13 SEER 3.5 Ton Air Conditioner. System is set and ready for the cooling season.

Lucas M.

Lucas M. Job Checkin

I installed a Carrier 80% 45,000 BTU Gas Furnace. I cycled the system to ensure functionality. System is operational upon departure.

I installed a Carrier 80% 45,000 BTU Gas Furnace. I cycled the system to ensure functionality. System is operational upon departure.

Adam  S.

Adam S. Job Checkin

I installed a Carrier 80% 70,000 BTU Gas Furnace. I cycled the system to ensure functionality. System is operational upon departure.

I installed a Carrier 80% 70,000 BTU Gas Furnace. I cycled the system to ensure functionality. System is operational upon departure.

Adam  S.

Adam S. Job Checkin

I installed a Carrier 96% Two-Stage 60,000 BTU Gas Furnace and a Carrier up to 17 SEER 2 STAGE 3 Ton Air Conditioner. I cycled the system to ensure functionality. System is operational upon departure.

I installed a Carrier 96% Two-Stage 60,000 BTU Gas Furnace and a Carrier up to 17 SEER 2 STAGE 3 Ton Air Conditioner. I cycled the system to ensure functionality. System is operational upon departure.

Isaiah C.

Isaiah C. Job Checkin

The capacitor is reading slightly out of specifications. I tried to spin motor and it is very tight. Motor has failed and needs replaced. Customer already has motor that he will install himself.

The capacitor is reading slightly out of specifications. I tried to spin motor and it is very tight. Motor has failed and needs replaced. Customer already has motor that he will install himself.