9320 S. Pole Rd
Oklahoma City, OK 73160
(405) 794-8900

Our Top Cities


Local Reviews
for luther, ok

Rated 5.0 out of 5 stars based on 5 customer reviews

Excellent service! As always

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great work, on time, great personality! Enjoyed the visit

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Isaac was a very nice polite young man! It was a pleasure having him service our unit!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best service

Prompt, quick, respectful, professional. Couldn’t ask for more.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for luther, ok

Jason B.

Jason B. Job Checkin

09FEB2024 Jason Brown Arrived for silver club fall tune up. Spoke with homeowner about the systems performance. We’re just trying to limp it along. We’ve already replaced the other two and need this one to last a bit longer. Cycled equipment at thermostat. Inspected coil, heat exchanger, plenums, gas lines, ductwork connections and all components at the furnace. Tightened wire caps and low voltage connections. Brushed debris and gunk out of evap. Removed blower assembly and tested balance and capacitor. Reinstalled blower and tested heat rise. Found blower wheel dirty and blower cap reading 4.5/7.5 mfd. spoke with homeowner about my findings we decided to leave it be for now. While I was out I noticed the newer York system struggling to start and may have some ignition issues. Equipment is under contract with another company.


Joe R.

Joe R. Job Checkin

No cool. Joe(JC)Ritchal 10/20/2033 I arrive to a call where we had recently replaced a blower motor and a fuse. I found the fuse Bad and since we had just replaced it I chose not to charge the fuse and after testing the system now I could not find any short in the system and it seems like it was just a defective fuse that got put on that took a few days to fill


Jason B.

Jason B. Job Checkin

Arrived for white shield no cool. Spoke with homeowner about the systems performance. It’s not cooling, also the downstairs system isn’t working either. Inspected upstairs system found fuse blown replaced fuse cycled equipment. Checked amps and voltage. Cycled equipment through all stages at the thermostat system is cooling properly. Inspected package unit. Found breaker tripped. Reset breaker and cycled equipment. Found condenser fan motor not running. Checked amps. Fan is completely out. Called homeowner with permission replaced condenser fan motor and cycled the equipment. Blower motor not moving air and coil freezing. Inspected blower motor found its out too. I do not have a blower motor on me at this time. Pausing appointment for now. Set disconnect into the off position. Homeowner wants to talk with husband about replacement. 11OCT2023 Jason Brown Arrived for previously discussed blower motor replacement. With homeowner permission I entered the residence and shut equipment off


Joseph K.

Joseph K. Job Checkin

I arrived for a silver club membership summer tune up. I inspected the system in the attic and found the system to be running well but the evaporator coil is rusted and the system is whistling due to low duct work. I inspected and cleaned the condenser and found the system to have some issues. I found the capacitor to be weak under load and the wire was starting to melt and blacken. I also found the contactor to be black and caked up with soot. I showed this to the homeowner and explained what and how the parts keep the system working. I gave options on replacing just the components or to install a compressor savor kit to help keep the system running as best as possible. The homeowner will go over the system with his wife and decide on what they want to do with the system.


Joseph K.

Joseph K. Job Checkin

I arrived to the location and found the family to be loading into their vehicle and they said they had a family emergency and would let me know if they needed anything.


Jason B.

Jason B. Job Checkin

01AUG2023 Jason Brown Arrived for new customer DIY install pressure test & vacuum. Confirmed pricing and scope of work. Pressure test system for 15 min at 412.2. Release nitrogen and pull vacuum to 282 microns. Shut off pump and perform vacuum decay vacuum rose to 483 microns. Opened refrigerant and cycled equipment. Air temp ~55 degrees system is operating normally.


Jason B.

Jason B. Job Checkin

05JUL2023 Jason Brown Arrived for summer tune up service. Spoke with homeowner about the systems performance. The garage system thermostat is out. The home system is working well. Inspected garage package unit found disconnect has a loose connection with the fuse. Washed both condenser coils. Cleaned out electrical cabinets, inspected disconnects, line voltage, condenser fans, abd blower motors. Verified coils were clean and checked charge. Found Carrier condenser is good condition fan at .9a compressor at 10a reversing valve switches properly and charge on point. Blower wheel and motor good. Found disconnect for garage package unit not making a good connection with fuse. Found blower capacitor reading 12/12.5 blower reading 3.5 and compressor at 14a all within manufacture specifications. Spoke with homeowner about my findings, we decided to go ahead and get the disconnect replaced. Will call with availability tomorrow. Both systems are clean and operating properly at this time


Jason B.

Jason B. Job Checkin

05JUL2023 Jason Brown Blue tune up full notes on white invoice.


Joseph K.

Joseph K. Job Checkin

Jake Kring. April 14 2023. I arrived for a previous customer no cool call. I first spoke with the homeowner and found that the system has leaked its refrigerant out again. We discussed the last visits and found that we had to put 8 pounds of refrigerant in the system on out last visit. We also found that Isaac had preformed a leak search in August 9 2020 and found the king valves to be leaking at that time. The homeowner wanted a up to date cost of replacing the king valves and adding what refrigerant is needed to get the system running. This system is 15 years old and i explained to the homeowners that I can replace or bypass the king valves but I would need to do another leak search to confirm that there are no more leaks in the system. I do not feel comfortable preforming a expensive repair on this system without permission preforming a leak search on the indoor system. The homeowner agreed for me to inspect the indoor system. I found the system to have undersized duct work on this


Sam J.

Sam J. Job Checkin

Sam J - arrived to Silver club member for fall tune up on horizontal furnace in attic. Spoke with customer and he explained there were not any cold spots in the house and thermostat is operating properly. System was running and thermostat was reading 69 when I arrived. Cycled thermostat off and began servicing system. Replaced (2) 20X25 and (1) 20X20 air filters in grilles. Removed coil cover to inspect heat exchanger and coil. Coil is clean but is rusting and shows signs of its age. Heat exchanger is free of any cracks or rust. Checked capacitor on blower motor which is good. Cycled system on from thermostat and watched for proper ignition. Then I checked amperage of inducer motor then blower motor once it cycled on. Ducts connected and insulated well, return clean of any trash or debris. Checked temperature difference at grilles, which was 45 degrees. Thermostat satisfied after several minutes after service was complete. Spoke with customer and informed him of the syst


Taylor P.

Taylor P. Job Checkin

Arrived at the home due to the system is not heating correctly. Arrived at the home and started looking at the system. The customer stated the system and home had been sitting unoccupied for 2 years. Started looking at the system and noticed mice had chewed up multiple wires so new thermostat wire would have to be ran. Also noticed blower wheel was completely caked with debris and also acorns. The transformer was also blown and will need to be replaced before any further repairs can happen. I spoke with the customer about getting a senior technician out to go over options before we start putting money towards repair due to the condition and overall shape of the system.


Jason B.

Jason B. Job Checkin

See white shield tune up.


Jason B.

Jason B. Job Checkin

29NOV2022 Jason B Arrived for fall tune up, spoke with Darrell about how the systems are doing. All good just getting our annual checkup. Replaced 20x25 filter on pack unit, cycled system into heating. Inspected blower heat strips, sequencers, Evap coil, and all electrical connections/ components. Blower 2.53a Cap 12.2/12.5 Heat strips ~20a Disconnect power to hp. Inspect capacitor, contactor, and all electrical components. Restore power and test rev valve and df timer. Cycle Heatpump in all stages. 44/44mfd 5/5 mfd cap Open ah disconnect power test fan balance and run cap. Cycle system In all stages. Verify amps and heat strips. Leave 20x30 filter with homeowner. Cycle system at thermostat. Inspect vents. Blower 2.5a No capacitor. Heat strips ~20a Both systems are working properly at this time.


ISAAC J.

ISAAC J. Job Checkin

Came out to call for a customer needing a system checked out in a home that belonged to his brother. His brother passed and he had no idea if the system works or not. I checked the system over and found the furnace shut off and the gas turned off. Customer confirmed that the home had propane. I turned the gas on and lit the pilot light. Tried to turn thermostat on, but it wasn’t operating properly. Discussed with customer about repair needed in order to get the system working properly. Customer approved replacement of the thermostat. I changed out the thermostat and made sure wiring was correct. Doublewide has no AC unit. Customer is aware of that and they will look into the possibility of getting a new one installed once they have everything figured out. After installation of thermostat, I turned furnace on and checked operation. Furnace cycled on and off just fine. Heat is operational.


Joseph K.

Joseph K. Job Checkin

I arrived for a silver membership summer tune up. I spoke with the homeowner and found that the systems are running to their expectations. I first cleaned all condensers and checked the systems operation and electrical readings. I found the capacitor to be weak with a dead frog on top of the capacitor. This can cause the capacitor to weaken and fail. I also found the contactor to be pitted and blackened. I made this aware to the homeowner and we decided to leave the system as it is.