really good service

Arrived within 11/2 hours from my initial problem call


Response from RS Andrews:

Thanks for you review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

My technician was nice knowledgeable and didn't mind the hundred questions I asked him since I know nothing about AC Units. Knew exactly what my problem was and the best solution to fix it.


Response from RS Andrews:

Thank you very much for your review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent and very professional service


Response from RS Andrews:

Thank you very much for your survey!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome work

We had an electrical circuit that wasn't working. Joshua with R. S. Andrews evaluated the problem quickly and fixed the problem within an hour. It was merely a loose neutral wire in the panel. The last electrician we had look at the problem couldn't find the problem and told us that we needed to change out the existing panel because it "wasn't compatible". Joshua told me that the only "problem" was that two of the breakers were a different brand and should be changed. It was a pleasure having an electrician who I would recommend to anyone!


Response from RS Andrews:

Thank you very much for your review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for acworth, ga

Jason H.

Jason H. Job Checkin

Pulled and reseated toilet. Installed new wax ring and supply line. Tested 7 times with no leaks. Sealed the base with silicone. Do not sit on for 24 hours. I found the flange to have an extension on it to make it floor height. Used an extra large wax ring with a horn.


Jason H.

Jason H. Job Checkin

Estimate for new water heaters. Old heaters are 16 years old. Pressure is 50 psi (good)


Jason H.

Jason H. Job Checkin

repair 3/4 pipe on the hot side of the water heater with pex pipe to stop water leak


Jason H.

Jason H. Job Checkin

Replaced a 40 gallon gas water heater with a new 40 gallon gas (Bradford White) water heater. Installed a isolation valve and a new thermal expansion tank. Hauled off old unit. Included a new condensation pump. All tested great.


Amber  D.

Amber D. Job Checkin

Found 3.5 ton ac 1 pound low on R22. checked furnace where noise was coming from-did not make any noise out of the ordinary. blower capacitor is slightly out of range. furnace and evaporator coil are 25 years old; the ac is 16 years old.


Robert   W.

Robert W. Job Checkin

found upstairs filter completely plugged-ac froze up. Replaced filter and set furnace to heat for 1 hour. Main floor air conditioner refrigerant ok. need to return to install a freeze stat on each unit-mr has ac units set to 60 which will keep the evaporator temp around freezing.


Robb C.

Robb C. Job Checkin

Completed Air Conditioner preventative maintenance on two units.


Joshua M.

Joshua M. Job Checkin

installed ext outlet at rear of home flush mount box with bubble cover.


Robb C.

Robb C. Job Checkin

Completed Air Conditioner preventative maintenance on two units.


Ben G.

Ben G. Job Checkin

Quoted to relocate gas line cut off with panel 4 feet to outside wall. 100 foot hot water line Tie in at desired location for future bar sink, tie in 20' cold water line for future bar sink.Install approximately 30 foot 1-1/2" drain line with studer vent requiring concrete cut out of 6"x 12' x8" to tie in to existing stack. Gas line relocation and water line addition and drain line addition.


Robb C.

Robb C. Job Checkin

Completed furnace preventative maintenance on one unit.


Robert   W.

Robert W. Job Checkin

Home warranty company replaced circuit board to main furnace. this board required the remote flame sense kit(using neutral from igniter to sense flame-new board does not recognize with this method). picked up remote flame sensor and installed. unit operational at this time. furnace is 22 years old and should be replaced soon.


Robert   W.

Robert W. Job Checkin

Upstairs unit operating in heat; yesterday the circuit board was not sending 24 volts to the gas valve until pushing in all the wire connections to the molex connector. More than likely the unit did the same thing intermittently.Replaced circuit board and rechecked every low and high voltage connection. Cleaned flame sensor, cleared draft port, checked gas pressure and temperature rise. all ok at this time. the duct work to this unit should be replaced soon; in poor condition.


Robert   W.

Robert W. Job Checkin

Upstairs furnace not sending 24 volts to gas valve. Pushed all connectors including the 2 wires for 24 volts into molex connector and unit came on. Tested five times unit fired every time. Either this is a loose connection issue or an intermittent comm issue with board.


Cameron Goss 2103  .

Cameron Goss 2103 . Job Checkin

Replaced basket strainer dude to old one was leaking.