Response from RS Andrews:
Thank you for taking time out of your day to complete our review!
Our serviceman, Tony Dorsch, called before arriving, was very prompt, diagnosed the problem, quoted a price and went immediately to work solving the problem. He was courteous, methodical, very neat and thorough.
Response from RS Andrews:
Thank you for taking time out of your day to complete our review!
Very professional kind and helpful
Response from RS Andrews:
Thank you very much for your review!
Tech was polite and very thorough, explaining things to me as he did all the necessary checks.
Tech installed new condensate pump, tech ran evacuation hose & tied coil drain into pump. Tech installed 24 volt safety break to furnace.
installed new customer, provided outdoor rated fan on back porch area. sealed the hole where wire exits the gutter system at fan location.
Calibrated 1 inch main water pressure regulator and expansion tank above water heater in crawlspace. Water pressure before 75 PSI new water pressure 60 PSI.
installed new fan and found out it was shipped defective. customer needs to purchase a new fan. remade bad splice job in gutter to properly protect the wiring. other splice kit was installed improperly.
Removed old dishwasher. Installed new customer supplied dishwasher with new water connector. Leveled and secured new dishwasher. Tested OK.
1-Replaced kitchen sin waste line from under neath cabinet all the way to basement. 2- Replaced owner provide Shower Head. 3- Tried to repair T&S valve but was not able to. Valve is seized up should be replaced . Note would need to cut tile wall to do said work. 4- Installed sediment trap and new gas cock also at water heater. 5-Installed new garbage disposal.
Performed main floor system repair. System 1 : Basement -Filter : 1-413 upgrade filter and brackets for both units. Connections and wires : Passed -Check electrical components : Passed -Rinsed out condenser coil : Cleaned -High voltage wiring : Passed -Blower motor : System 1 : 4.3 Amps -Condenser fan motor : System 1 : 0.99 Amps -Compressor : System 1 : 10.29 Amps -Dual capacitor : System 1 : 60/5 uf -Contactor : System 1 : 243 Volts across -Breaker : System 1 : 40 amp -Monitor refrigerant levels : System 1 : Low : 75 Psi High : 200 Psi Super heat : 10 'F Sub cool : 12 'F -Evaporator coil : System 1 : Possible leak in circuit. -Inspect flue/vent pipe : System 1 : passed -Check gas valve and gas line : System 1
fr $2,085.00 panel replacement Per Andrew, Chris to go out and make repairs
installed cust supplied faucet cust says faucet still leaking.
preformed small diagnosis for ceiling fan light kit replacement of ceiling fan customer provided * upstairs bedroom* panel maintenance
Gave estimate to run three water lines for hose bibs and rough in and install 1 laundry tub.
Completed Air Conditioner preventative maintenance on one unit.
Replaced the outdoor heat pump TX V evacuate system recharged monitor system is working normally at this time this is a warranty part and labor job.
Install lennox 2.5 ton 14 acx air conditioner complete system in closet upflow 14" wide 809% 70k btus code items, brought vent up to code, no thermostat needed, filter rack 16x25x1.
Completed Air Conditioner preventative maintenance on one unit.