Jason H.

Jason H. Job Checkin

We furnished wired, and installed a 50 amp 240 volt plug and dedicated circuit for a Tesla charger. We had to cut Sheetrock. We do not patch said Sheetrock. We furnished a permit with the county for said work.


Jason H.

Jason H. Job Checkin

No cool, Found system freezing up due to shorted contactor and low refrigerant levels, Installed new contactor, Ck/change filter, Clean/rinsed cond coil, Installed time release treatment Cleint Aware system needs further attention for permanent fix/repair also made aware system can freeze and leak water causing property damage, Suggested upgrading equipment. Told will get $350 repair credit if upgrades system.


Jason H.

Jason H. Job Checkin

No cool on 2 systems, Upstairs system, Unit has low refrigerant levels and dirty condensor coil equipment 23 years old suggested upgrading system. Downstairs system, Found unit completely out of refrigerant has major leak equipment 23 years old suggested upgrading system. Mr waiting on financing speaking Chris W to have done. Mr decided to purchase 2 full systems, Lennox full sys XC14 with ML180


Jason H.

Jason H. Job Checkin

NO COOL TWO SYSTEMS. SET THERMOSTAT TO COOL. DOWNSTAIRS SYSTEM BREAKER TRIP OUTSIDE. APM DRAW ON COMPRESSOR AND FAN MOTOR NORMAL. CHECKED FREON LEVELS AND FREON GOOD. UPSTAIRS SYSTEM LOW ON FREON NO SERVICE CAP ON ANY OF THE PORT TO PREVENT LEAKS. REPLACED CAPS ON AC UNIT. ADDED 2lbs 410a. RECOMMENDED SMILEY CLUB PLAN. TWO SYSTEMS IN ATTIC.


Jason H.

Jason H. Job Checkin

Ac unit is not cooling age unknown basement. Fixed


Elsworth D.

Elsworth D. Job Checkin

Installed audio optional stat with audio selected mode in home of visually challenged customers home.


Jeremiah W.

Jeremiah W. Job Checkin

SERVICE CALL WATER LEAKING FROM UNIT. FOUND PVC DRAIN CLOGGED. INSTALLED FLOOD CONTROL PACKAGE. INCLUDES SAFETY SWITCH,PAN TREATMENT,PTRAP AND PVC REPAIR. TEST DRAIN. SYSTEM IS DRAINING PROPERLY.


Harry S.

Harry S. Job Checkin

Plumbing : Estimation to convert gas water heater to tankless .