They do not send the same person back after installation, over charges for permits, lacks coordination of services to complete final inspections.
Response from SunCoast Home Solutions:
I am so glad we were able to provide you excellent service! Cheers!
Great job very professional. Great job by Kylie in the office.
Response from SunCoast Home Solutions:
Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.
Excellent
Response from SunCoast Home Solutions:
Thanks for sharing your review with us and the community.
CAME WITH OUT A SERVICE CALL.. CHANGED C B CHECK SERVICE AND ALL OK. CLEAN NEAT AND ON TIME. THATS WHAT A SERVICE CALL SHOULD BE.. THANKS
Response from SunCoast Home Solutions:
Thank you for sharing your kind words with us. It means the world to us and to our entire team!
Response from SunCoast Home Solutions:
Your kind words mean a lot to us. Thanks for leaving such a positive review!
Great job
Response from SunCoast Home Solutions:
Many thanks for taking the time to share your feedback with us. We’re very happy to hear that we met your expectations!
Fpl metter can need to be replaced corrosion from fpl sticker Surge protector Outdoor main breaker 200 amp per code Indoor challenger recall panel main lug 200amp Grounding system Inspection needed Ground wire to sub panel Feeders is aluminum replace to copper 10 feet each run
Did maintenance on a 3 ton unit cleaned and cleared drain line for clogg, Checked electrical values and freon levels, refill the drain line
Installed return grill installed installation ac lines,sprayed foam on line chase
Today for this job we completed wiring for AC junction box inside attic. Inside the junction box they had the neutral wire connected incorrectly, it needed 220. The unit outside was only getting 110 because of the miswiring. we also installed new AC disconnect up inside of the attic because the original one was charred from the fire that occurred at the property. we removed old smoke detector that was in the hallway outside of the bedrooms. It was an old cutting box. We replaced it for a 1900 box. We screwed the 1900 box onto the stud and put around mud onto it. We also verified that the circuits inside of the kitchen were new wires. For the dishwasher range disposal microwave. The wiring for that for the dryer and the washer was already taken care of and was redone in PVC. The water heater already was taken care of as well with PVC half-inch for the dryer it was three-quarter and for the washer was half-inch. The water heater also had a toggle switch installed which acts as a disconne
Ductwork Restoration: Addressing a client's concern of uneven cooling in their home, our inspection revealed loose and damaged duct connections within the HVAC system. Through meticulous restoration, we ensured a proper seal, improving airflow and resolving temperature inconsistency issues. The client's home now enjoys even and consistent cooling, and we recommended periodic duct inspections for continued efficiency.
Today for this job, we ran one number 12 wire for the bathroom GFI and also we ran 14 two wire for a light inside of a closet in the bedroom. We also wired the Disconnect for AC unit and verify that it came on. When we come back, we need to trace the rest of the circuits to make sure they’re all good.
Dedicated line for range in the garage 40amp four prong 3/4 pvc run 40 feet and couplings 90 lb 3/4 #8 wire 8/3 2/40 Siemens Outlet 40 amp four prong and plate Straps 3/4 Junction box
Upon troubleshooting found a bad compressor and board. Suncoast will handle warranty process no charge on materials labor only.
Remove exisiting Ac unit and replace with a Rheem single stage Ac unit. Installed to manufactors recomended installation practices designed by engineers for the best performance to last longer and lower energy bills for the specific model. Our 37 point installtion pracitices makes sure you are getting a quality Suncoast insualtion.
I checked the voltage and found that it was only 12 V on the B phase. I removed and replaced the existing transformer, resulting in a final voltage of 220 V. The customer ordered the shipping time to be about 3-4 days.
Customer has three outdoor light fixtures that they would like removed them replace We will be providing fixtures
Need three phase transformer, that one he got is too small for elevator brendt is waiting for the supplier to give the costumer an estimate
Customer has two switches and one timer switch he would like remove them replace customer is supplying materials
Generator mainteneace scheduled for 4/17 for Briggs and stratton 20 KW generator.