18341 E. El Buho Pequeno Gold
Canyon, AZ 85118

Local Reviews
for gilbert, az

Rated 5.0 out of 5 stars based on 5 customer reviews

Great Service. Fair Price.

My dryer broke on October 30. I was able to get an appointment for November 1 (understandable that they didn't have anything available on Halloween). I was given a 3:00 PM to 5:00 PM window. Our tech arrived promptly at 3:00 and had our dryer up and running in about 30 minutes. The cost was within what I had planned to pay (after doing research online for similar dryer malfunctions). I would definitely use these guys again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic!

David was honest, friendly, and did not charge for unnecessary fixes.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ash

Great and quick service. Spencer did a great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

5 Stars

3rd Time I have used these guys, and a different tech each time. Reliable, good price every time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, friendly staff and really fair pricing.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for gilbert, az

Paul  S.

Paul S. Job Checkin

CONCERN: Microwave is not working. CAUSE: Found turn table motor has failed. CORRECTION: No repairs made at this time, customer declined repair and has decided to update all of her kitchen appliances.


Paul  S.

Paul S. Job Checkin

CONCERN: Washer is not draining or spinning DIAGNOSTIC AND CAUSE: Inspected washer for proper output voltage from washer control to the washer motor, voltage output is normal at the time of testing. Inspected washer pump, Found washer pump failure. CORRECTION: Replaced washer pump and tested. Operation now normal. No leaks upon completion.


Paul  S.

Paul S. Job Checkin

CONCERN: Dryer is making a loud noise when tumbling. DIAGNOSTIC AND CAUSE: Inspected dryer barrel operation, operation normal. Inspected blower wheel for restrictions, no restrictions in or around blower wheel. Found dryer drum support rollers failed. CORRECTION: Replaced rollers, belt, and idler pulley. Operation now normal


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports washer water inlet is not working properly. Will continue to fill. Shut off outside water and turn water back on, and the washer will go through a cycle without issue. CAUSE: Found washer water valve failed. CORRECTION: Replaced washer water valve and tested. Operation is now normal. NOTE: After repairs were completed inspected for leaks, no leaks at the time of completion


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection. Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal. No leaks upon completion. CONCERN: Customer reports refrigerator Ice Maker flap isn’t shutting all the way CAUSE: Found bad Ice Maker flap motor CORRECTION: Replaced Ice Maker Flap Motor and tested. Operation now normal. No leaks upon completion.


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports dishwasher is not draining. CAUSE: Found debris stuck in drain pump impeller restricting operation. CORRECTION: Removed drain pump and cleared debris. Tested unit operation is now normal. No leaks upon completion.


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports refrigerator is leaking water. DIAGNOSTIC AND CAUSE: Inspected water supply line for leaks, no leaks at the refrigerator water supply line. Inspected internal water refrigerator water lines for leaks, internal refrigerator water line are normal at the time of inspection. Inspected refrigerator defrost drain line for water leaks, found the source of the leak coming from the refrigerator defrost drain. Removed freezer panel to inspect for clogged drain line. Found the defrost drain restricted with ice and debris. CORRECTION: Cleared the refrigerator defrost drain of ice and debris, operation now normal. No leaks upon completion. CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports dryer is not heating. DIAGNOSTIC AND CAUSE: Inspected dryer for proper voltage from the wall to the cord terminal block, voltage normal. Inspected voltage from terminal block to dryer control assembly, voltage normal. Inspected continuity on all thermal safety thermostats, all thermal safeties are normal. Inspected continuity at heater element, found dryer heating element failed. CORRECTION: Replaced dryer heating element and tested. Operation now normal.


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports oven is not heating DIAGNOSTIC AND CAUSE: Tested for proper voltage from wall outlet to terminal block Voltage good. Tested voltage from terminal block to control, voltage good. Tested voltage from control to ignitor, voltage good. Found oven ignitor has electrical short. CORRECTION: Replaced ignitor and tested, operation now normal. CONCERN: Customer reports smelling gas when broiler is turned on. CAUSE: Oven safety gas valve leaking gas. CORRECTION: Replaced oven safety gas valve and tested. Operation now normal. NO LEAKS UPON COMPLETION.


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports washer won’t go through spin cycle and hot water continuously leaks into washer. CAUSE: Found washer electronic water valve assembly failed. CORRECTION: Replaced washer electronic water valve assembly and tested. Operation now normal. Removed and Replaced Washer Hot and Cold Stainless Steel Braided Hoses. NOTE: After repairs were completed inspected for leaks, no leaks at time of completion


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports refrigerator is leaking water. Inside refrigerator CAUSE: Found bad water filter head. CORRECTION: Replaced customer supplied water filter head and tested. Operation now normal. No leaks upon completion.


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports washer is making a loud noise when running. CAUSE: Found washer bearing and shaft failed. CORRECTION: Replaced washer bearings, seal and rotor shaft, tested for leaks. Operation now normal. Remove and Replace Stainless Steel Braided Hoses


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports Oven is making a clicking noise*** CAUSE: Found Infinite switchs are shorted causing them to Arc CORRECTION: Replaced Both left side switches and the RR infinite switch


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection. Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal. No leaks upon completion.