Installed new 6-inch IC-rated LED recessed lighting in living room per NEC standards. Cut precise openings in drywall using a RotoZip tool. Ran new 14/2 NM-B romex cable from lighting circuit. Wired fixtures to junction boxes using proper connections and cable clamps. Connected grounds to metal cans. Tested lights on dimmer switch before securing trims.