Great Service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

awesome service

prompt , knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Work is good but takes forever to get someone out

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for annapolis, md

James G.

James G. Job Checkin


James G.

James G. Job Checkin


Chicago  C.

Chicago C. Job Checkin


Dwayne  B.

Dwayne B. Job Checkin

Antonio 830a DO NOT DROP Kitchen Suppression Inspection Semiannual Kitchen Inspection Equip Desc: (1) Ansul R-102 6G, () , () Kitchen System(s) Deficiency for Ansul R-102 6G: Same deficiency’s remain from last inspection: TERMINAL LINK ABOVE PIZZA OVEN NEEDS TO BE RELOCATED UNDER FRYER **no filters covering v-style pizza oven hood, could result in a accidental discharge**


Richard  J.

Richard J. Job Checkin


Richard  J.

Richard J. Job Checkin


Thanh N.

Thanh N. Job Checkin


Richard  J.

Richard J. Job Checkin


Jason  .

Jason . Job Checkin


Richard  J.

Richard J. Job Checkin


Paul M.

Paul M. Job Checkin


Chris B.

Chris B. Job Checkin


Jason  .

Jason . Job Checkin


Dwayne  B.

Dwayne B. Job Checkin

CURTIS 10-1030A 443-623-7884 cell Kitchen Suppression Inspection Semi-Annual Kitchen Inspection Equip Desc: Inspect (4) 6 Gal. Ansul Systems Inoperable Deficiency for Ansul R102 Wells 6 gallon: Same deficiency’s remain: concession stand 1,2,3,4(all systems are the exact same) ansul 6gal WELLS ventless hood (1.5galx4) -appliances need to be interlocked to system, when hood is off appliance should not be able to turn on -no electric shutdown to fryer or grill -no alarm bell -paper filters need replaced and metal ones need cleaned due to heavy grease build up ***liability disclaimer form added*** concession stand 4 -thermal detectors must have short in wiring, when interlocked is plugged in system trips, as of now only way to activate system in the event of fire in with the remote pull -filters also need changed on it, filter and service light are on


Dwayne  B.

Dwayne B. Job Checkin

03/03 CHEF JOHNATHAN 10-1030A Kitchen Suppression Inspection Ansul R-102 3-gallon: Semi-Annual Kitchen Inspection Equip. Desc.: ANSUL 3-gallon and (1) Ansul 6 Gallon Deficiency for Ansul R102 66gallon Front hood: Salamander was added to equipment line-up and needs protection. **Repipe drops for proper coverage** System has 19 flows already