7668 Standish Place
Rockville, MD 20855
(301) 861-0972

Our Top Cities


Local Reviews
for bowie, md

Rated 5.0 out of 5 stars based on 9 customer reviews

Operations Director

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

great customer service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

customer servoce

great customer service. The techs did a great job with the panel replacement.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Professional

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

EXCELLENT SERVICE

Technical team are always prompt, polite and respectful of the environment. Any issues identified are forward immediately for same day price quote - much appreciated.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Good company to work with

The internal office team and the technicians are very accommodating and professional. They have worked with our community for more than six years and service continues to be very positive. Stay healthy, safe and thank you!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Quality Service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Inspection quick and easy

  • Overall Experience
  • Quality
  • Price
  • Convenience

Bladensburg SDA Church

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for bowie, md

Dwayne  B.

Dwayne B. Job Checkin

10-11am perry 252 671 4290 Emergency / Exit Lights and Portable Extinguishers Inspection Annual Emergency/Exit Lights (approx 26 units) Annual Extinguisher Inspection (approx 10) Inoperable Deficiency: Exit light front entrance Bad charging board and needs replacement Emergency light inside office Bad charging board and needs replacement Exit light (Sanctuary entrance) Bad charging board and needs replacement Exit light (Emergency exit in sanctuary) Bad charging board and needs replacement Exit light (Sanctuary exit to stage) No battery back up Emergency light (Rear stage hallway) Bad charging board and needs replacement Exit light (Daycare) Bad charging board and needs replacement Combo light x2 (2nd outside classroom) Bad charging board and needs replacement Deficiency: 5lb abc electrical room is due for 6 year maintenance Completed Kclass extinguisher is due for hydro testing Completed 5lb abc extinguisher (sanctuary) due for 6 year maintenance Completed 5lb abc e


Dwayne  B.

Dwayne B. Job Checkin

10-11am perry 252 671 4290 meeting you Kitchen Suppression Inspection Ansul R102 1.5 Gallon Kitchen: Semi-Annual Kitchen System Inspection Inoperable Deficiency for Ansul R102 1.5 Gallon Kitchen: Ansul 1.5 gallon: system upgrade needed ** Ansul 1.5 gallon Improper coverage above ranges 6 burner and 10 burner range lacks protection. **6 burner range is half way outside of the hood.** **U shaped detectors being used, stainless steel (3) V shape scissor clips need to be installed.** UL-300 upgrade needed Loose wiring inside ottoman (Junction box needs to be installed) **Shock hazard** 1/4 piping through out the system


Dwayne  B.

Dwayne B. Job Checkin

Portable Extinguishers Inspection Annual Inspection Dept: EXTING Equip Desc: (4) EXT


James G.

James G. Job Checkin


Chicago  C.

Chicago C. Job Checkin


James G.

James G. Job Checkin


Jason  .

Jason . Job Checkin


Logan A.

Logan A. Job Checkin


Paul M.

Paul M. Job Checkin


Paul M.

Paul M. Job Checkin


Brian L.

Brian L. Job Checkin

Portable Extinguishers Inspection


Chicago  C.

Chicago C. Job Checkin


John  R.

John R. Job Checkin


Chicago  C.

Chicago C. Job Checkin


Chicago  C.

Chicago C. Job Checkin