malve 9-10p malve meeting you 443-616-9682 no cooking install (1) K class ($275), and (2) 5 lb. ABC. Kitchen Suppression and Portable Extinguishers Inspection Semi-Annual Kitchen Inspection Equip Desc: (1) Ansul 9 Gallon System Install (1) K-Class and (2) 5lb ABC extinguishers. Create location form. Inoperable Deficiency: Ansul 9 gallon Improper coverage above (Spinning Grillers) 32inx35&3/4in #1 Stock range 18inx18in #2 Stock range 18inx18in 3) 1F nozzles protecting 6 burner range are clogged and needs replacement** (1f nozzles were replaced 2/8/2021 with swivel adapters) Fryer 24inx14in **2) 230 nozzles are clogged and needs replacement** #1 Wok 13&1/2in #2 Wok 13&1/2in #1 circular flat top range 30in (currently has 290 nozzle as protection.) *Clogged* #2 circular flat top range 30in (1n nozzle protecting appliance) *Swivel adapter needed (Swivel adapter added 2/8/2021) Flat top grill 24inx36in (1n nozzle needs swivel adapter to properly aim nozzle to appliance.) swivel ada


Paul M.

Paul M. Job Checkin


Paul M.

Paul M. Job Checkin


Paul M.

Paul M. Job Checkin


Paul M.

Paul M. Job Checkin


Paul M.

Paul M. Job Checkin


Dwayne  B.

Dwayne B. Job Checkin

Annual Inspection Dept: EXTING Equip Desc: (9) EXTINGUISHERS Portable Extinguishers Inspection


Dwayne  B.

Dwayne B. Job Checkin

tom 1230 see tom cell 410-404-1591 meeting you Kitchen Suppression Inspection Semiannual Inspection Dept: KITCHEN Equip Desc: (1) RANGEGUARD 4 GAL Alarm Int: No Inoperable Deficiency for RangeGuard Unknown 4 Gallon Back wall by dish washer: Same deficiency’s remain from last inspection: Range Guard 4 Gallon 4 gallon cylinder is due for hydro testing MFD ( 8 burner range, 2 burner/ flat top griddle, Grill and fryer lacks detection and protection. System lacks gas shut-off gas valve frozen with heavy grease. No local bell interlock. **UL-300 upgrade needed** Deficiency for 5 ABC End of bar: 5lb abc extinguisher located at the end of the bar is due for hydro testing. Last 6 year maintenance was performed in 2013.


Richard  J.

Richard J. Job Checkin


James W.

James W. Job Checkin


Dwayne B.

Dwayne B. Job Checkin


Fuzzy H.

Fuzzy H. Job Checkin


James G.

James G. Job Checkin


Chris B.

Chris B. Job Checkin

Kitchen Suppression Inspection