Kitchen Hood Suppression System - NON COMPLIANT Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiencies were found on order 14523730 Current nozzle coverage will require changes 6 burner range and griddle will require back shelf coverage with nozzle type 11982 nozzles (4 and can reuse one in place now) Client Responsibility: If back shelf is removed this will not be needed Replace duct nozzle with proper one to meet compliance Client Responsibility: Move commercial griddle under exhaust canopy to meet code. Repair of these deficiencies is essential to overall life safety. Please see attached compliance quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512 Fire Suppression Repair Nozzle for the duct protection not the proper one. Nozzles for 10 burner with back shelf not the proper type and position. Nozzle for the griddle protection n


Nicholas L.

Nicholas L. Job Checkin

Kitchen Hood Suppression Systems - NON COMPLIANT Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiencies were found on order 13745452 All 3 system past due for the 12 yr hydrostatic services on cylinders, cartridges and regulator tests Kettle fryer system Hydrotest service required on all 3 Ansul cylinders Regulator test required Replacement of double tank cartridge required Repipe each cylinder for a 12 flow max Fryer Front System Hydrotest service required on all 3 Ansul cylinders Regulator test required **- Replacement of double tank cartridge required ** Ensure coverage is met from Ansul manual 4-34.3 as well as remove 3 nozzles from the front of one line and 2 from the rear of the other Fryer Rear System Hydrotest service required on all 3 Ansul cylinders Regulator test required Replacement of double tank cartridge required Ensure coverage is me


Nicholas L.

Nicholas L. Job Checkin

Portable Extinguishers and Fire Suppression Inspection Annual Fire Extinguisher Inspection Semiannual Kitchen Fire Suppression System Inspection Masterbox Plugout-Devens Fire Box #149 Deficiency: Kettle Fryer System is non compliant due to system cylinders and co2 cartridge are due for hydro test. These are due every 12 years per nfpa. No signs of a regulator test and this is due every 12 years as well. 1 of 3 cylinders is over drawn. Will need to adjust accordingly. Need to update coverages on the appliance line. Both Fryer systems need all cylinders and co2 cartridges hydro tested. Also no signs of regulator tests. These are all due every 12 years per nfpa. 4 of 6 cylinders are over drawn. Will need to adjust accordingly. Also need to update appliance line coverages to both systems.