Ashley O.

Ashley O. Job Checkin

Service Call: Commercial Overhead Door Issue: The operator has stopped working and the door is stuck closed. Work Completed: The technician realigned the photo eyes and reattached the track that was loosen when the door was hit. The technician lubricated all moving components on the door and tested multiple time to ensure safe and proper operation.

Service Call: Commercial Overhead Door 
Issue: The operator has stopped working and the door is stuck closed.
Work Completed: The technician realigned the photo eyes and reattached the track that was loosen when the door was hit. The technician lubricated all moving components on the door and tested multiple time to ensure safe and proper operation.

Ashley O.

Ashley O. Job Checkin

Service Call: Commercial Overhead Door Issue: The door will not close, a truck backed into it. The technician replaced the track that was bent, the roller and the hinges. The technician balanced the door and tested multiple times for safe and proper operation.

Service Call: Commercial Overhead Door
Issue: The door will not close, a truck backed into it.
The technician replaced the track that was bent, the roller and the hinges.
The technician balanced the door and tested multiple times for safe and proper operation.

Ashley O.

Ashley O. Job Checkin

Service Call: Commercial Overhead Door Issue: The door is extremely heavy Work Performed: Replace 2 broken springs, and 2 hinges. Tested door multiple times for safe and proper operation.


Ashley O.

Ashley O. Job Checkin

Service Call: Commercial Hoist Issue: When the button released to control hoist, the hoist is not responding to it, and keeps going down. Work performed: Removed protective cover from unit and inspected, Tested hoist multiple times to find out the problem, the solenoid is sticking causing hoist to continue to lower when the down button is released. Replaced solenoid then tested multiple times for safe and proper operation.

Service Call: Commercial Hoist 
Issue: When the button released to control hoist, the hoist is not responding to it, and keeps going down.
Work performed: Removed protective cover from unit and inspected, Tested hoist multiple times to find out the problem, the solenoid is sticking causing hoist to continue to lower when the down button is released.
Replaced solenoid then tested multiple times for safe and proper operation.

Ashley O.

Ashley O. Job Checkin

Service Call: Commercial Overhead Door Issue: The Door is wedged and will not move Work Performed:Both door cables were off the drums and tangled around the shaft. Reset the cables, and balanced the door. Tested the door multiple times for safe and proper operation.


Ashley O.

Ashley O. Job Checkin

Service Call: For Overhead Door Issues: Cables came off the drum. Work Performed: Reset Cables Tested for safe operation

Service Call: For Overhead Door

Issues:
Cables came off the drum.

Work Performed:
Reset Cables
Tested for safe operation

Ashley O.

Ashley O. Job Checkin

Service Call Work Performed: Secure door Reset cables Operate and test Advise customer not to let door slam on the ground Check operation


Ashley O.

Ashley O. Job Checkin

Service Call Work Performed: -Tested and inspected operator. -New operator required. -Pictures of Micanan operator are in photos -Operator is left side drive. -Re connect existing photo eye and safety edge. -19’ electric scissor lift required -Make sure to confirm operator mounting plate can be reused.

Service Call

Work Performed:
-Tested and inspected operator.
-New operator required.
-Pictures of Micanan operator are in photos 
-Operator is left side drive.
-Re connect existing photo eye and safety edge. 
-19’ electric scissor lift required 
-Make sure to confirm operator mounting plate can be reused.