Jeff D.

Jeff D. Job Checkin

Condo inspection in Oceanside, Ca. The AC did not work in this unit so will recommend it to be looked at by a licensed HVAC contractor prior to the end of the clients contingency period. Please call us for more information on our Oceanside property inspections 760-525-5340. The Property Inspection Pros.

Condo inspection in Oceanside, Ca. The AC did not work in this unit so will recommend it to be looked at by a licensed HVAC contractor prior to the end of the clients contingency period. Please call us for more information on our Oceanside property inspections 760-525-5340. The Property Inspection Pros.

Jeff D.

Jeff D. Job Checkin

Inspecting a property in oceanside. Please call us for more information 760-525-5340

Inspecting a property in oceanside. Please call us for more information 760-525-5340

Jeff D.

Jeff D. Job Checkin

We have the capability of sending 2 inspectors out on larger homes. Find out more at www.tpips.com, 760-525-5340

We have the capability of sending 2 inspectors out on larger homes. Find out more at www.tpips.com, 760-525-5340

Jeff D.

Jeff D. Job Checkin

Water stains are observed at the waves and side wall below the roof which is a good indicator that the roof is leaking in this area. This area should be further evaluated by a licensed roof contractor.

Water stains are observed at the waves and side wall below the roof which is a good indicator that the roof is leaking in this area. This area should be further evaluated by a licensed roof contractor.

Jeff D.

Jeff D. Job Checkin

Picture of a drip leg or sediment trap at a furnace in the garage. These are a great device to help catch sediments from entering a gas fired appliance such as a furnace or water heater. Most manufacturers require them to help void the warranty. When not present we highly recommend them and are not often found on older gas fired appliances here in San Diego. For more information on drip legs or sediment traps please call us at 760-525-5340.

Picture of a drip leg or sediment trap at a furnace in the garage. These are a great device to help catch sediments from entering a gas fired appliance such as a furnace or water heater. Most manufacturers require them to help void the warranty. When not present we highly recommend them and are not often found on older gas fired appliances here in San Diego. For more information on drip legs or sediment traps please call us at 760-525-5340.

Jeff D.

Jeff D. Job Checkin

Several missing and worn roof shingles observed at this roof in Oceanside. This condition could result in a leaky roof.

Several missing and worn roof shingles observed at this roof in Oceanside. This condition could result in a leaky roof.

Alon H.

Alon H. Job Checkin

All openable fireplaces must have a non-combustible hearth in front of it. Some flooring contractors take them out to keep the flooring seamless. This can be a hazard if sparks jump out of the fireplace and land on the combustible flooring.

All openable fireplaces must have a non-combustible hearth in front of it. Some flooring contractors take them out to keep the flooring seamless. This can be a hazard if sparks jump out of the fireplace and land on the combustible flooring.

Jeff D.

Jeff D. Job Checkin

Exposed piping at the water heater may indicate that there was a partial water supply line re pipe or that there may have been a slab leak. When this condition is observed we recommend asking the seller to verify what the repairs were. We inspect SD!

Exposed piping at the water heater may indicate that there was a partial water supply line re pipe or that there may have been a slab leak. When this condition is observed we recommend asking the seller to verify what the repairs were. We inspect SD!

Jeff D.

Jeff D. Job Checkin

Gas leak test conducted at all accessible gas piping. At The Property Inspection Pros we exceed the normal standards of practice by doing a gas leak test on all accessible gas piping in the property’s we inspect.

Gas leak test conducted at all accessible gas piping. At The Property Inspection Pros we exceed the normal standards of practice by doing a gas leak test on all accessible gas piping in the property’s we inspect.

Bruce C.

Bruce C. Job Checkin

This home was built in early 1960 and has a large number of roof defects, negative slope drainage on the side of the garage and a large retaining wall with major cracks. Additionally the existing flue pipes are transite which we will recommend be removed by a licensed contractor. The water heater is at the end of its' useful life and the master bath shower does not have a threshold to prevent water from entering the living space. We recommend having a threshold installed to prevent flooding.


Jeff D.

Jeff D. Job Checkin

Wood retaining wall has damaged wood and is leaning. This condition will only continue to worsen over time. This retaining wall should be further evaluated by a structural engineer and be replaced by a qualified licensed contractor.

Wood retaining wall has damaged wood and is leaning. This condition will only continue to worsen over time. This retaining wall should be further evaluated by a structural engineer and be replaced by a qualified licensed contractor.

Jeff D.

Jeff D. Job Checkin

The water heater water temperature was tested with a thermal camera and found to be with in normal range. Water temp over 125 is considered to be too high and a scolding hazard. As a doctor would we do Housecall Property Inspections to satisfy all of our clients needs.

The water heater water temperature was tested with a thermal camera and found to be with in normal range. Water temp over 125 is considered to be too high and a scolding hazard. As a doctor would we do Housecall Property Inspections to satisfy all of our clients needs.

Bruce C.

Bruce C. Job Checkin

Newer roof with exposed nails, rolled roof valley should both be sealed at flashing to prevent water intrusion. Garage firewall has openings that should be sealed to prevent a garage fire from spreading to the living space and a fire rated entry door is also recommended.

Newer roof with exposed nails, rolled roof valley should both be sealed at flashing to prevent water intrusion. Garage firewall has openings that should be sealed to prevent a garage fire from spreading to the living space and a fire rated entry door is also recommended.

Jeff D.

Jeff D. Job Checkin

Oceanside buyers property inspection reveals leak at the sink waste pipe in the garage and a leak at the pool solar equipment on the roof.

Oceanside buyers property inspection reveals leak at the sink waste pipe in the garage and a leak at the pool solar equipment on the roof.

Jeff D.

Jeff D. Job Checkin

Home Inspection