Local Reviews
for portola, ca

Rated 5.0 out of 5 stars based on 2 customer reviews

Adam has been very good

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best service !

Quality service, showed up on times, concerned about keeping house clean when working inside house. Would recommend their service and plan on using again ! Thank you !


Response from Home Energy Experts Inc.:

Thank you Thomas! We greatly appreciate your trust in us! Sincerely, Eric Robnett

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for portola, ca

Randy M.

Randy M. Job Checkin

FIREPLACE MAINTENANCE • cleaned the unit from dirt, dust, and debris • inspected the glass • inspected the rope seal on the window • inspected the flue and or combustion chamber • inspected the flu cap assembly • inspected the fan assembly • checked the fans alignment and bearings • inspected the burner assembly for deterioration • cleaned the orifice • cleaned the pilot assembly from carbon build up • cleared the pilot orifice • polished the thermopile • polished the thermocouple • polished the ignitor rod • cleaned and wiped down under the unit • cleaned the glass as best as possible • relayed an ember bed • replaced log-set to manufacturers specs • tested for gas leaks • tested for carbon monoxide • Tested all functions of the fireplace as well as the fan assembly • Turned unit on and tested the thermopile and thermocouple • Inspected the systems performance • Adjusted as necessary for a clean burn FIREPLACE MAINTENANCE • cleaned t


Randy M.

Randy M. Job Checkin

Mobile Home Furnace Maintenance • Cleaned furnace • Cleaned burner compartment • Cleaned flame sensor • Cleaned filter door • Replace filter • Verified no gas or CO leaks • Blower 6.0 amps • Inducer motor 1.0 amps • Blower capacitor 9.9 MFD • Cleared pressure switch hose Air Conditioner Maintenance • Cleaned AC • Vacuumed debris from condenser • Wash condenser coil • Torque Schrader cores • Tightened king valves • Check for refrigerant leaks at service valves • Clean filter grill • Replaced filter • Condenser fan motor .8amps • Check contactor • Blower cap 9.9 MFD • Blower 6.0 amps • Inspect coil Capacitor 45/5mfd Compressor 5.0amps Recommend keeping up on maintenance. Also 521 compressor savor (319) at the end of your maintenance plan they recommend installing the 521 compressor savor 3-5 years after install to help the compressor last longer and put less stress on the unit when starting up Gave brochure of air scrubber and


Randy M.

Randy M. Job Checkin

Customer was looking for a mini split just in the kitchen for less then 4500.00 let him know that we could not get that low on ac or mini split Offered emerald air for the whole house he wasn’t interested very nice but had a guy in grass valley tell him he could do a heat pump system for 4500.00


Adam B.

Adam B. Job Checkin

BOILER REPAIRS: I installed I installed the new components into the boiler system to get it functioning without having a fault code. Once objectives were completed I pumped the glycol back into the system that had to be removed to drop pressure off the system. I turned the unit on and had cycled it between heating and hot water to verify operation. Everything is back up and running as well as no water leaks. ITEMS REPLACED: - starting flue shroud - seals for the flue shroud - high temperature flue limit switch - return temperature sensor - water pressure sensor - daughter circuit board, controls the sensors - repaired a minor leak - installed a debris guard over daughter board


Eric R.

Eric R. Job Checkin

WARRANTY The issue this time around was that the boiler cut out again as well as our heat pump system. What I found with the heat pump is that where it is located and after the weather we had gone on this previous Sunday two days ago, the melt off went great down and funneled into the heat pump outside. All this water that went into the unit wound up freezing up And cause the unit to stop working. As a temporary fix I had to remove a bunch of the ice around the unit especially around the fan blades so that we can get it back on and running. There is a little bit of ice at the bottom but I did get the unit running prior to leaving and was making sure the house was getting back up to proper temperatures. To rectify this problem we need to either pull the air conditioner away from the wall or some sort of water diverter needs to be installed up on the roof. As far as the boiler goes, this time around it vaulted out with a code reading F03 which indicated that the return temperature s


Eric R.

Eric R. Job Checkin

WARRANTY CALL: The claim was that the master bedroom was not heating up as well as it once did or at all. What I determined was that the one zone valve control that controlled the master bedroom was set for zone six. When I made the call for heat on that zone I heard some chattering from that zone valve controller. Being that we freed up one zone by adding our heat pump air handler system which was on the other zone valve controller, I had to rewire the system and that specific zone to work off of the other zone valve controller. This master bedroom zone valve is now on the other zone valve controller and is still on the number six zone valve. I ran through the system thoroughly after rewiring the controllers and made sure that everything was functioning as it should as far as the air handler that feeds the master bedroom was turning on any heating as well as the in floor heat provided from the boiler. After thoroughly checking everything and checking the operation I also checked the


Eric R.

Eric R. Job Checkin

Demo, removal, and recycle the old equipment, and installation of new Lennox Air Handler as well as Lennox Heat Pump. We will provide permits and inspections as well as coordinate the process. We will remove the unit from communicating with the boiler and this package system will be it’s own separate system. We will need to provide the proper duct modifications to be able to fit the equipment into the existing space. The line sets will remain due to the location but we will flush the line set and clear all existing refrigerant out of the lines. This air handler and heat pump are the top of the line pieces of equipment on the market today. They are the most efficient as well as the quietest units out. The units have 65 stages of heating and cooling. The estimate is not going to include a heat strip ( additional secondary heat ), to add this into the system it is going to be an additional $1000.00. This will provide the heater coil as well as the electrical (220v) run to the unit and p


Eric R.

Eric R. Job Checkin

This estimate is to perform service work on the boiler. I will be quoting the replacement of a air vent, cleaning of the air separator, and to flush the system and fill with the proper mixture of glycol (heat transfer fluid). By having glycol in the system it will have better heat transfer than water, it will clean the build up on the piping, and prevent freezing of the lines. Per customers request I will perform this service work at the same time as the install.


Eric R.

Eric R. Job Checkin

Built and sent the estimate for he air handler and the service work. Find in estimates!


Eric R.

Eric R. Job Checkin

Came out today to inspect the fireplace above the garage due to another company coming out and saying it was unsafe. What I found is that it is a freestanding propane stove, it is completely filled with such, the glass door is broken and has about a 1/8’’ gap Between the panes of glass. I don’t believe the unit was ever converted from natural gas to propane but I can’t tell for sure without getting into the unit which I won’t do due to the broken glass window. The venting is a single wall 4 inch pipe meeting a B vent elbow sticking out of the wall. Being that it goes through an interior wall I can’t verify the clearance to combustible but I don’t think it is meeting the certain clearances. I talk to her on the phone and gave her a couple of options of optional heat sources but she doesn’t want to Spend that amount of money on such a small apartment. She is probably just going to get an electric fireplace to put up there or continue to use the space heaters. I am formed


Eric R.

Eric R. Job Checkin

I am going to put together an estimate on replacing an air handler that is currently not working at the moment and also reconfiguring his boiler controls because they are not done properly. Also she wants an estimate as far as service goes for me to introduce glycol into the system because they do not live here full-time. I informed him that this is going to take me a couple days to work up and I will email it over to him once I have completed.


Eric R.

Eric R. Job Checkin

I installed the proper circuitboard into the condenser outside. I tested the system and cycled through heating and cooling and Randy each setting for a little bit to make sure that it wasn’t doing what he had said it was with the previous circuitboard. He did say that it would happen now on colder temperatures so we will have to see how it works for next winter. I’m going to email Tom my contact information about the referral for his neighbor.


Eric R.

Eric R. Job Checkin

Give up dear to install the new condenser electrical control board and after replacing the board found that the unit was not operating properly. I got on the phone with technical support which took a while to get through, but once I did re-started running through quite a bit of diagnostics to figure out what was going on. We came to realize that it is not the right control board for this unit. I called western to give them hell on ordering the wrong board. I spoke to Tony and verified that he’s ordering The right board as well as I got the part number that is needed so that this does not happen again when we receive the new board. It is going to take 5 to 7 days Tony said, it is coming from Georgia. Thomas up here his understanding and said to just let him know when it comes in and he will meet us up here again


Eric R.

Eric R. Job Checkin

Warranty Came up to troubleshoot the problem with the hyper heat Mitsubishi mini split. After being on the phone with technical support for a while and testing multiple functions with the unit they came to the realization that the control board in the outdoor unit has it issue with the software. They are going to have us get a hold of Western Nevada supply for getting the new control board to bring up here. I cycled the unit on cooling as well as heating end it was satisfying the temperatures rather quickly. The refrigerant charge is good so that is not the issue it must be the circuitboard.