140 Icon Ct.
Sparks, NV 89441
(775) 786-4357

Job Locations
for dayton, nv


Map of Dayton NV
Eric R.

Eric R.


Job Checkin

Air Conditioner Maintenance: - Cleaned AC - Vacuumed debris from condenser - Wash condenser coil - Torque Schrader cores - Tightened king valves - Check for refrigerant leaks at service valves - Clean filter grill - Replaced filters - Condenser fan motor 1.0amps - Compressor 17.2Amps - Check contactor - Run Cap MFD - Inspect coil - Static pressure R/A: .4WC - Static pressure S/A: .42WC Average lifespan for an AC is 15-20 years. This current AC is 15 years old which puts it in prime position for major component failure to occur. Suggest preparing to replace AC Current air conditioner uses r22 refrigerant. R22 has been phased out since 2010 and starting January 1, 2020 it will not longer be made nor able to import into the United States *HIGH STATIC PRESSURE IN DUCTWORK* -This high static pressure is costing the customer money each month in higher energy bills. High static pressure puts extreme stress on the furnace/air conditioner and causes it to overwork itself. This