I had Mason Heating & Air scheduled for A/C tune-up service. Our unit is old, operational but was having noise when the fan kicks in. Technician Mike was able to narrow down the issue and identified condenser motor and fan need to be replaced. Mike arranged procuring the parts quickly working with the back office and get it fixed as soon as the parts arrived. Thank you Mike, I will highly recommend

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, pleasant visit, resolved problem

Hassad is always pleasant and took professional care of us. Resolved refrigerants problem!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Hassan was outstanding! He was efficient, thoughtful, and thorough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service and Timely Response

Hassan was assigned our service call and came out promptly and professionally. Got us back up running and helped us get our house warm again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very thorough evaluation of our system!

Mike was great! Very professional and explained everything. Wants to make sure everything is done correctly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Awesome Price, Extremely Friendly and knowledgeable technician (Hussain)

Hussain, the Technician, that came to our home was very polite, courteous, and knowledgeable. Hussain made us feel very comfortable and answered all of our questions. Hussain is a great example of exemplary customer service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service , great price

Very good and very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for mason, oh

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Byrant heating and cooling system. The thermostat was wired correctly, but the wires were smashed together between the wall and back plate for thermostat. I connected the common wire and re-wired the thermostat. I cycled the systems and is working properly at this time. Advised the customer if this happens again, the thermostat is most likely bad.

I completed a diagnostic on a Byrant heating and cooling system. The thermostat was wired correctly, but the wires were smashed together between the wall and back plate for thermostat. I connected the common wire and re-wired the thermostat. I cycled the systems and is working properly at this time. Advised the customer if this happens again, the thermostat is most likely bad.

Hassan H.

Hassan H. Job Checkin

I gave an estimate to install a Carrier 80% 90,000 BTU Gas Furnace and a Carrier 13 SEER 3 Ton Air Conditioner. I included in the estimate is a 1 year free service maintenance agreement.


Hassan H.

Hassan H. Job Checkin

I gave an estimate to install a Carrier 80% 135,000 BTU Gas Furnace. I included in the estimate is a 1 year free service maintenance agreement.


Hassan H.

Hassan H. Job Checkin

Unable to provide service.


Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Lennox AC unit. I found the condenser has a drier vent directly behind it, which caused the coil is be COMPLETELY clogged on all sides. I washed the coil. From what I see the system is running ok now, but if I were to guess, I'm thinking the blower motor went out which caused unit to freeze. The customer will wait for the unit to fail.

I completed a diagnostic on a Lennox AC unit. I found the condenser has a drier vent directly behind it, which caused the coil is be COMPLETELY clogged on all sides. I washed the coil. From what I see the system is running ok now, but if I were to guess, I'm thinking the blower motor went out which caused unit to freeze. The customer will wait for the unit to fail.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Goodman system. I found the inducer motor boot is completely cracked and broken off. We will have to order a new one.


Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Goodman system. I found the inducer motor boot is completely cracked and broken off. We will have to order a new one.


Hassan H.

Hassan H. Job Checkin

I completed the spring tune up on a Carrier 13 SEER 3.5 Ton Air Conditioner. I visually inspected the furnace. Checked voltage and amps. I inspected the evaporator coil. I checked the temperature difference across the coil. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored the system. Operating normally at this time.

I completed the spring tune up on a Carrier 13 SEER 3.5 Ton Air Conditioner.  I visually inspected the furnace.  Checked voltage and amps. I inspected the evaporator coil.  I checked the temperature difference across the coil.   Checked refrigerant charge, voltages and amps.  I rinsed the condenser coils with water.  Cycled and monitored the system.  Operating normally at this time.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Westinghouse AC unit. The customer already had coolant added and was told there was a leak. I gave the customer options. The customer will let us know.

I completed a diagnostic on a Westinghouse AC unit. The customer already had coolant added and was told there was a leak. I gave the customer options. The customer will let us know.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Goodman AC unit. I found the evaporator coil was clogged and the dual cap had failed. I washed the condenser and cut and cleared the drain line due to it being clogged. Either the TXV is flooding the coil or not enough air is going through the coil. The customer will let us know what they decide to do.

I completed a diagnostic on a Goodman AC unit. I found the evaporator coil was clogged and the dual cap had failed. I washed the condenser and cut and cleared the drain line due to it being clogged. Either the TXV is flooding the coil or not enough air is going through the coil. The customer will let us know what they decide to do.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a heat pump. I found the contactor is pitted and the capacitor was bad. The customer decided to opt out for a new unit.

I completed a diagnostic on a heat pump. I found the contactor is pitted and the capacitor was bad. The customer decided to opt out for a new unit.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Lennox AC unit. I found the AC not coming on due to the disconnect flipped upside down. I also found the suction line covered in oil right around valve. This was due to a failed Schrader core, so I replaced the Schrader core. I checked the charge and found the unit running 27psig suction and dropping. I gave the customer options.

I completed a diagnostic on a Lennox AC unit. I found the AC not coming on due to the disconnect flipped upside down. I also found the suction line covered in oil right around valve. This was due to a failed Schrader core, so I replaced the Schrader core. I checked the charge and found the unit running 27psig suction and dropping. I gave the customer options.

Gage R.

Gage R. Job Checkin

I installed a Five Star 96% 2 Stage Variable Speed 80,000 BTU Gas Furnace 5T 21" and a Carrier 16 SEER 3.5 Ton Air Conditioner. I cycled and monitored the systems and they are both operational at this time.

I installed a Five Star 96% 2 Stage Variable Speed 80,000 BTU Gas Furnace 5T 21" and a Carrier 16 SEER 3.5 Ton Air Conditioner. I cycled and monitored the systems and they are both operational at this time.

Hassan H.

Hassan H. Job Checkin

I completed a service call on a Carrier 16 SEER 3 Ton Air Conditioner. I found a small hole in the silicone around the filter rack. I sealed the hole and ran the system. The system is operational at this time.

I completed a service call on a Carrier 16 SEER 3 Ton Air Conditioner. I found a small hole in the silicone around the filter rack. I sealed the hole and ran the system. The system is operational at this time.

Hassan H.

Hassan H. Job Checkin

I completed the spring tune up on a Trane air conditioner. I visually inspected the furnace. Checked voltage and amps. I inspected the evaporator coil. I checked the temperature difference across the coil. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored the system. Operating normally at this time.

I completed the spring tune up on a Trane air conditioner.  I visually inspected the furnace.  Checked voltage and amps. I inspected the evaporator coil.  I checked the temperature difference across the coil.   Checked refrigerant charge, voltages and amps.  I rinsed the condenser coils with water.  Cycled and monitored the system.  Operating normally at this time.