7077 Beach Dr SW
Ocean Isle Beach, NC 28469
9107542200

Local Reviews
for oak island, nc

Rated 4.9 out of 5 stars based on 180 customer reviews

Thanks!

We love our service plan, and greatly appreciate that Chris was able to solve our problem quickly. Competent, knowledgeable, and efficient, on the day before Thanksgiving! Thanks, Chris!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Mystery solved

Heating and cooling replaced in the heat of summer didn’t spend too much time testing for heat. Not until the seasons really changed was the heat pump asked to work. Fan worked but unit didn’t respond with heated air … until Chris found the problem and reprogrammed the thermostat. That was all it needed. Thanks, Chris.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service representative was timely and efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

On time and very nice!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

Joe Walters provided a very thorough service and explained everything as he went.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thanks for keeping us cool!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great HVAC Service

Chris was very thorough and explained everything as he went through the service. He was also very professional, very friendly and very customer service oriented.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for oak island, nc

Christopher T.

Christopher T. Job Checkin

Found fuse blown on the low voltage side And disconnect off


Christopher T.

Christopher T. Job Checkin

Found that the defrost board on the outdoor unit is bad bypass to defrost board for now until we get the new defrost board system only runs in heat mode


Christopher T.

Christopher T. Job Checkin

Found a thermostat bad and I also install wire the thermostat wrong This is a callback from earlier this morning


Christopher T.

Christopher T. Job Checkin

Txv replacement


Chris H.

Chris H. Job Checkin

2016 Trane Unit not heating properly. Checked system and found it to be low on charge. Added 1 pound refrigerant. Re checked system and unit is working at this time.


Chris H.

Chris H. Job Checkin

Warranty call Daikin remote controls both heads. There is one head on each floor. Heads are mounted approximately the same location on far wall with only about 10 feet of distance between the heads. According to Daikin, remotes automatically connect to any nearby unit


Chris H.

Chris H. Job Checkin

2015 Trane System was working upon arrival. Owner stated that overnight the outdoor unit would cut off and come back on. Checked pressures. Checked capacitor. Checked amp draw. Found no issues at this time. System has been running since arrival. Indoor temp was at 77. System was likely going through defrost cycles.


Chris H.

Chris H. Job Checkin

Found thermostat operating properly. Stat would start system on demand and turn off once satisfied. Found no issues with system. Customer requested she wanted to manually be able to control system so disabled auto feature, could have been on auto before arrival. At arrival system was turned completely off.


Chris H.

Chris H. Job Checkin

2017 Trane Callback. Several previous visits. Heat would not come on. Found thermostat would blank out and come back on when there is a demand for heat. Checked system and had power. Fuse was not blown. Found contactor in air handler with some burns on the coil. Replaced contactor. System started and ran for around 30 minutes. System went into a defrost cycle during visit. Tested heat strips. System appears to be working properly.


Chris H.

Chris H. Job Checkin

2013 Carrier/R22 2018 Goodman Customer stated that outdoor unit was coming on and off. Checked system and found it had been in defrost. Customer was unfamiliar with heat pumps, explained defrost cycle. Checked pressures, amp draw and capacitor. System is R22 but in good working order at this time. No other issues found with system. Customer signing up for Silver membership. There is a guest house with another system.


Lionel L.

Lionel L. Job Checkin

Found and repaired a short on the coil temperature sensor


Lionel L.

Lionel L. Job Checkin

2014 Trane dual package unit system maintenance. Leda is undecided as to whether she will renew due to past expense of repairs right here at Christmas


Christopher T.

Christopher T. Job Checkin

Ductwork need to be Reinsulate in the information on the duck work is 40 years old and there’s bare spots on the trunk line The water coming from the the trunk line it condensating from bare metal


Chris H.

Chris H. Job Checkin

Replace reversing valve Solenoid and defrost board. Started system and ran for about 10 minutes. Set heat to 65. Owner is going to call office to pay invoice.


Christopher T.

Christopher T. Job Checkin

Found the outdoor txv bad will not run in heat mode