Great work and resolved the issue quickly
They were all professional and very nice. Explained what they were doing and or did. Cleaned up.after themselves, couldnt even tell they were here. Great service!! Thank you.
Response from A+ Heating & Cooling- Electrical:
Thank you, John, we like to provide our customers with excellent service through hard work, explaining procedures, so the client understands the work being done and keeping a clean workspace!
When i arrived I inspected the unit and found a wire not connected properly. Fixed problem. Unit is running properly at this Time. Job completed
Replaced damaged gaspac blower door . Job completed
When i arrived tstat and indoor were working but no cooling, later found condenser on lockout defrost went for too long. I couldn’t recreate the issue but if problems persist , recommending changing replacing board. No sensors are tripped and book reads possible cause defrost. Job completed unit is running at this time
Tstat was off when I arrived after finding the rite unit I noticed the drain line upside down. Causing float switch to trip. Unit running now job completed
Diagnosed bad head on nest thermostat. Needs replacing h/o said she’ll take care of it. No other problems or concerns
Replaced rollout switch unit and unit fired up. No other problems or concerns
When I arrived I checked the new unit and noticed that the suction Line wasn’t that hot i then put my guages and noticed it was slightly undercharged I added a few oz-lb and unit is fine I also reconfigured his nest thermostat for the weather at hand and showed the homeowner how to switch it back when it’s hot again to maximize savings/efficiency. No other problems or concerns job completed
When I arrived there was no power to thermostat after troubleshooting i found that rollout switch is bad there’s obvious signs that moisture came in the unit somehow and damaged the rollout switch. I had reset the switch unit came on but the problem will continue unless the rollout switch is replaced spoke with homeowner and she agreed on the rollout switch. See pics for reference on which rollout
Completed routine maintenance and cleaned and wiped electronic air filter (trane). No other problems or concerns. Job completed
Crossover duct beneath home was found to be torn and disconnected.
Check system out to see why the Delta T home system is isn't it not higher than 15 in check the emergency heat strips they were not running check to shoney check the charge to make sure charge was good System is cooling right now but not cooling properly
2019 Lennox heat pump/ gas pack package unit. Checked voltage, amp draw, connections, pressures, capacitors, contactors, ensured all connections throughout system were properly tightened down and in proper place, cleaned coils , cleaned drain line, put new wire nuts on thermostat wires inside unit due to size of wires, this system is working properly at this time no issues were found.
Checked install. No drain connections made at this time
Ductwork beneath the home was found to be in poor condition. The return is partially collapsed and multiple ducts are torn or missing from the Trunkline. The equipment is currently in good working order, however the duct system is in need of update
Prepaid maintenance on a 2007 train heat pump split system. Found on the outdoor unit a 35 µF capacitor was bad ,also a 10 µF was bad as well. Replaced both capacitors, found on the indoor unit the evaporator coil is in really bad shape due to corrosion . Also all the insulation in the floor of the air handler is heavily damaged due to water. Evaporator coil is at fail point and can leak at any time. Recommending replacement of system due to the use of old refrigerant as well as upcoming repairs . Customer will speak to his wife and let us know what he would like to do.