7077 Beach Dr SW
Ocean Isle Beach, NC 28469
9107542200

Local Reviews
for tabor city, nc

Rated 4.7 out of 5 stars based on 3 customer reviews

Good Service


Response from A+ Heating & Cooling- Electrical:

Thank You, please refer us to your Neighbors, friends, and family

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

Great people


Response from A+ Heating & Cooling- Electrical:

Hi Pansy, we would love an opportunity to discuss your recent experience and find out what we could do in the future to make your next visit a 5-star one!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt Professional Service

Up to date tech...with old fashioned personal service!!


Response from A+ Heating & Cooling- Electrical:

Thank You, please refer us to your Neighbors, friends, and family

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for tabor city, nc

Scott S.

Scott S. Job Checkin

Performed Maintance on a 2016 Rheem heat pump system. Checked all voltage amperage and capacitor all are good at this time. Checked pan float switch it is working normal, cleared drain line. Found contactor on outside condenser partially melted on one side. Showed customer and advised they replace it, customer said ok to replace contactor.


Lionel L.

Lionel L. Job Checkin

2018 Ruud system condenser was locked out on high pressure, checked over system after resetting everything is running and working properly pressures are good, filter is clean. no further action is needed


Christopher T.

Christopher T. Job Checkin

Sytem got stuck in defrost mode Replace the Defrost Board and all systems are working properly at this time


Christopher T.

Christopher T. Job Checkin

Found that the plugs for The selenoi valve not plugged in properly plugg in new check system out made sure the system would go in to heat and cool all systems working properly at this time 2020 ruud


Chris H.

Chris H. Job Checkin

2019 Ruud package Checked pressures. Checked voltage and connections throughout. Checked amp draw on compressor and fan motors. Checked capacitor. Cleared drain. Cleaned coils. No issues found. Unit is working properly at this time.


Lionel L.

Lionel L. Job Checkin

Replace Reversing valve Solenoid customer called Office and paid over the phone yesterday 2/2/22


Lionel L.

Lionel L. Job Checkin

2020 Ruud system reversing valve solenoid needs to be replaced


Chris H.

Chris H. Job Checkin

Goodman package 10+ years System working during the day but goes out overnight. Checked system and found defrost board to be bad. Was unable to manually put system in defrost so this board would need to be replaced. Evaporator coil is rusted. Fire ants have also made a mound going into evaporator coil section. Blew dirt out from unit the best I could. No data tag is present on system so cannot determine exact age but it is at least 10 years. Due to to price of repair, rusted coil and overall condition of system replacement is advised. Since system will not go into defrost advised customer to set thermostat to emergency heat at night and below 40 degree weather. Current indoor temperature is 74. Customer has requested a comfort advisor to come out about a replacement. Turned over to Jack


Chris H.

Chris H. Job Checkin

2020 Ruud System not heating properly. Checked system and during visit did not find any issues. Pressures were good. Amp draws were good. Checked heat strips. Tested defrost. Did not find any issues. During visit indoor temp had reached 70 degrees. Customer is going to monitor system and let us know if it acts up again. See notes


Lionel L.

Lionel L. Job Checkin

Repair leak on condenser coil and charge system 7lbs 410A. no charge per management


Christopher T.

Christopher T. Job Checkin

Found system low on refrigerant Customer did not want to do leak search Added 1 pound of refrigerant to top system off System is heating properly 2018 Goodman heat pump He is sending a check in the mail for 133.44


Christopher T.

Christopher T. Job Checkin

Defrost board under part warranty replaced


Christopher T.

Christopher T. Job Checkin

Defrost board will not go in to defrost causing the outdoor unit to ice over when it is 32 or below


Christopher T.

Christopher T. Job Checkin

System is a street AC unit customer does not want to use heat strips to heat the house with also the only way the fan will come on is if you put it in either cool or emergency heat


Christopher T.

Christopher T. Job Checkin

Bad blower motor and condenser motor New system He going to call the office to pay