17300 N. May Ave, Ste A
Edmond, OK 73012
405 657-2484

Have any feedback for us? We'd love to hear it! Call us at (405) 888-5253 and let us know how we are doing.


Local Reviews
for norman, ok

Rated 5.0 out of 5 stars based on 7 customer reviews

Highly Recommended

Showed up when they said they would, Professional Service, Fair Price, Would Recommend to Family and Friends.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent technician

Arrived early and very knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Service!

Excellent work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Extraordinary service. Unbelievable price!

Friendly, courteous, thorough service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

He was prompt and quick.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very careful & competent

quick service--covered all bases

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for norman, ok

Jesse E.

Jesse E. Job Checkin

System needs replaced to be able to cool entire house. House is approximately 1600+ sq. Ft. 2.5 ton system can cool 1000 sq.ft. Supply plenum has a tap out of the top, so system can’t build any head pressure to supply house properly. Need to replace plenum and install a new 4 ton system to be able to cool entire home.


Kressy D.

Kressy D. Job Checkin

NE ac fan motor is running max amps, capacitor is good so fan motor is just on its last leg I recommend replacing it System also low on 410a not very much but the charge is off could’ve always been this way NW ac capacitor is 35/5 reading 30.42/1.01 out of tolerance fan motor not running.. this is system downstairs that’s not cooling, replaced capacitor and system is cooling as it should, charge is low on this unit about the same East ac capacitor 35/5 reading 14.49/1.47 out of tolerance needs replaced, fan motor running 0.86 and data plate max is 0.75 but system is cooling as it should just working really hard without that capacitor, replaced capacitor and fan amps dropped to 0.64 Washed condensers and changed all filters and replaced broken filter grill All systems cooling as they should


Jesse E.

Jesse E. Job Checkin

OG&E tune up, added 1 lbs.of Freon 410a. Txv was slightly stopped up.


Kressy D.

Kressy D. Job Checkin

Performed iManifold tune-up for OG&E Commerical Energy Efficiency Program. System was running at 79 percent efficiency at start of job. After air flow adjustments and cleaning, unit was running at 91% efficiency.Performed iManifold tune-up for OG&E Commerical Energy Efficiency Program. System was running at 79 percent efficiency at start of job. After air flow adjustments and cleaning, unit was running at 91% efficiency.


Kressy D.

Kressy D. Job Checkin

Checked all system components, everything is working as it should, system is 20yrs old, condenser is has been beat up with hail fairly bad but it’s not causing an issue with the system performance, system is cooling well just not as efficient as it could be because of the age of all of the components, condenser has hail damage which is not causing a problem today but it’s only 71 degrees this morning so I can’t promise that when we get to the 90’s and 100’s that we won’t have an issue but today it’s ok Inside of burners are pretty rusted over but found no cracks Customer asked about replacement so I put together a couple of quotes for replacement options


Kressy D.

Kressy D. Job Checkin

Spring tune up


Jesse E.

Jesse E. Job Checkin

Found that breaker is bad not allowing enough power to system so it could start up, also noticed that condenser is pretty dirty and needs serviced, I recommend getting into our maintenance program to help preserve your equipment and help lower your energy cost Customer needs to have our electrician come out and change out the 30A breaker in the small panel on the bottom right, Customer is available anytime after 1230pm just let her know that we are on the way


Jesse E.

Jesse E. Job Checkin

System was double filtered Removed filter from inside furnace Cleaned flame sensor System working when I left


Jason B.

Jason B. Job Checkin

Replacement of GFI in exterior location. License #012028


Jesse E.

Jesse E. Job Checkin

Wiped system down, checked blower cap, checked igniter,checked flame sensor, made sure drain is flowing, checked home for CO, cycled system to ensure good operation, washed filter, pressure switches working properly... system heating 100%


Cris K.

Cris K. Job Checkin

Doing og&e tune ups at an upscale case & associate apartment complex.


Jason B.

Jason B. Job Checkin

Performing a duct inspection on a home. When another company quotes over $35,000 to replace two units, it’s best to call and get another estimate. We give free second opinions!


Cris K.

Cris K. Job Checkin

Service call


Cody S.

Cody S. Job Checkin

Just finished up a charge on a unit.


Cris K.

Cris K. Job Checkin

Doing a free tune on a valued customers air conditioner.