Job Locations
for addison, tx

Justin S.

Justin S. Job Checkin

Checked flame sensors and ignighters, replaced filters and performed co test as well as inspected flu pipe and blower motors . Found droplets of water coming from roof down side if flu pipe onto furnace . I let the customer know and they are going to have a roofer come out .


Joel S.

Joel S. Job Checkin

Post install walkthrough on recently installed equipment. Primary drain is completely clogged up. Upon arrival thermostat was blank due to the inline float switch being tripped. In order to keep the air conditioning working I had to bypass the float switch and let the water collect in the secondary pan. Catherine is aware of this. Verified refrigerant charge is good. System is cooling properly at this time.


Bob E.

Bob E. Job Checkin

I closed this out and am going to do another. They do not want me out there until after 4pm. I have other calls scheduled and I can’t Dispatch while this one is open.


Joel S.

Joel S. Job Checkin

Post install walk-through on recently installed equipment. Inspect air handler verified primary drain is clear at this time. Checked outdoor unit. Refrigerant level is good at this time. Picked up folder installers left behind.


Joel S.

Joel S. Job Checkin

Install thermostat under warranty. Verified zoning dampers were opening properly and operating at manufacture specifications.


Joel S.

Joel S. Job Checkin

1050 thermostat is non responsive to the church. Is possibly the reason Denise has had issues recently. Upon arrival today indoor temperature was 74°. I will check with the office in the morning to see if there are any available at the shop. If not they will order one and keep in touch with Denise on the ETA of thermostat.


Francisco  S.

Francisco S. Job Checkin

Perform 1 system AC maintenance checked refrigerant levels and split. Washed condenser coil. Changed 20x25x4 filter. Checked amps on blower and condenser system is cooling properly at this moment


Joel S.

Joel S. Job Checkin

Customer stated that after I left on the visit on Friday everything was working properly. Today I verified that all zones are opening and closing properly. She is still wanting her front door installed.


Joel S.

Joel S. Job Checkin

Adjust zone dampers to slow down airflow in upstairs bedroom and top of stair landing. Also to Pushmore to Denise‘s bedroom. Need to order two newMotors for the zone dampers. One that controls the kitchen and bathroom next to kitchen is not operating.


Francisco  S.

Francisco S. Job Checkin

Arrived to grill condensating I believe we need to increase both the main truck line of the duct and the duct itself seal the boot with mastic and weatherstrip the grill to stop the sweating will contact office with info


Joel S.

Joel S. Job Checkin

AC performance tune up times one system. Upon arrival I cleaned up the front door hardware. It was all over the door handle and deadbolt. The paint on the door looks very unprofessional. Changed out and supplied 20 x 25 x 4 filter. Inspect blower, evaporator and ductwork. Cast thermostat for proper operations. Verified primary drain is clear at this time. Check outdoor unit. Refrigerant level acceptable at this time. Washed condenser coil. Made a note on the maintenance form for the holly bushes to be trimmed back away from the condenser. Barely enough room to wash condenser coil. We need at least 18 " all the way around condenser so that it may be serviced. System is operating at manufacturer specs at this time.


Cole K.

Cole K. Job Checkin

Repaired whistling PVC issue on an AC system in Addison


Cole K.

Cole K. Job Checkin

Repaired whistling PVC issue on an AC system in Addison


Cole K.

Cole K. Job Checkin

Repaired whistling PVC issue on an AC system in Addison


Cole K.

Cole K. Job Checkin

Repaired whistling PVC issue on an AC system in Addison