577 Sterling Drive
Richardson, TX 75081
972-591-0199

Local Reviews
for mckinney, tx

Rated 4.5 out of 5 stars based on 13 customer reviews

Good service

I thought he spent too much time on his phone. Made me wonder how much he was concentrating on the job at hand.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Joel was very polite and super quick.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great response, service and price on a weekend

Service in McKinney within an hour on Saturday no extra charge.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Poor service, broken promises, waste of time

  • Overall Experience
  • Quality
  • Price
  • Convenience

Knowledgeable employee

Jason was very passionate and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and spring tune up

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

The best. Thats why we always ask for him.

We prefer Joel, because we know he will be honest with us. He has been serving our Airconitioner for at least 18 years.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service. Helpful and informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Really good service. Well done

Through check of the system. Informed me of the results and expectations of the system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for mckinney, tx

Joel S.

Joel S. Job Checkin

Heating performance tuneup times one system. Change out filter client supplied. Inspect blower, evaporator, ductwork and heat exchangers. Found no stress cracks and heat exchangers. No carbon monoxide or gas leaks detected in home. Test all safety features high limits and rollouts. Check thermostat for proper operations. System operating at manufactures bags at this time.


Francisco  S.

Francisco S. Job Checkin

Completed maintenance inspection, recommend surge protectors for insde units. Flame patterns were good, no gas or carbon monoxide leaks. Changed out media filters. Also homeowner purchased surge protectors.


Jeff S.

Jeff S. Job Checkin

Completed diagnosis, installed Turbo run capacitor, 25/5. Freon was low, declined repairs at this time.


Joel S.

Joel S. Job Checkin

No cool upstairs. Found float switch tripped because the drain was clogged up. Isolated both units with the quick blast we installed and cleared with nitrogen. The drain line itself was clear. There was some buildup in the P-trap. I treated with drain solution and system is flowing properly at this time.


Jeff S.

Jeff S. Job Checkin

Outdoor compressor/fan motor was not working. Installed Turbo run capacitor 45/5. Also customer purchased gold membership, 1st visit in fall.


Jeff S.

Jeff S. Job Checkin

Completed maintenance check, drains lines are clear, filter is clean, refrigerant levels are in range. Everything seems to be working properly.


Francisco  S.

Francisco S. Job Checkin

Arrived to condenser not coming on found bad capacitor replaced with turbo system came on system cooling at this moment


Francisco  S.

Francisco S. Job Checkin

Arrived to primary drain clogged unclogged it with nitrogen and strap drains advised to have a plumber come check out the 90 degree fitting when pvc drains comes out to see if it’s pitching correctly that could be the culprit system draining properly at this moment


Joel S.

Joel S. Job Checkin

No cool. Condenser not running. Found condenser fan motor defective. Removed and replaced with new universal. System cooling properly at this time


Francisco  S.

Francisco S. Job Checkin

Arrived to primary line clogged installed quick blast and nitrogen clear the line system draining properly


Francisco  S.

Francisco S. Job Checkin

Perform 2 system maintence washed condenser coils changed supplied filters checked refrigerant levels and capacitors both system are cooling properly at this moment


Joel S.

Joel S. Job Checkin

Return today to install another blower motor upstairs. System came on and is operating properly at this time. # no


Jeff S.

Jeff S. Job Checkin

Completed diagnosis, possible leak in upstairs evaporator coil. Customer will call home warranty for service.


Joel S.

Joel S. Job Checkin

Replace defective blower motor on upstairs unit. Check charge and added1 pound of R 22. System cooling properly at this time.


Jeff S.

Jeff S. Job Checkin

Completed diagnosis, system was giving me a 126 error code. Repaired corroded wires inside of condenser. Replaced about 4ft of low voltage wire, and reset fault codes. Recommended maintenance agreement, declined at this time.