Jacob P.

Jacob P. Job Checkin

I arrived to the unit not cooling at all. Both upstairs and downstairs thermostats had displays on and showing it was cooling. I immediately went into the attic and found the furnace to be off and the zone control board to be blank. I went into the attic and verified power was on for both indoor and outdoor equipment. I then went back upstairs and began diagnosing the issue. The unit is properly receiving the correct voltage but the zone control board has failed completely. I showed my findings to our client. I was also able to speak with her husband over the phone. He elected to have me preform a temporary bypass of the zone board until an electrician is able to come out to the home and fix any outlying issues. I cautioned the home owners that the bypass is temporary and if any residual electrical damage occurs it could damage more components on the equipment. I believe all of the problems are correlated to the original power outage from the storm that happened a few weeks ago. They


Jacob P.

Jacob P. Job Checkin

I arrived at our clients home to the unit not cooling properly. He had recent power outages due to storms in the area. I proceeded to the outdoor unit fist and tested all the electrical components. Everything passed inspection. I then went inside and found the zone control board blinking with a low pressure error. I removed the discharge air temperature sensor and diagnose it to have failed. I showed my findings to our clients and we discussed how I would need to replace the sensor before I could further test the unit. I had a replacement sensor and tested the unit. I let the unit run for 20 minutes without any other lockouts or issues. I checked the refrigerant pressures and measured the temperatures at the indoor unit. The pressures were reading abnormal. Indicating low Freon pressures and I was only getting 13° drop at the indoor unit. We discussed how the unit may be low on Freon due to a leak. Our client had to get ready for work and he elected to monitor the unit for now. I w


Alex R.

Alex R. Job Checkin

Cooling AC system maintenance Performed tune up and found no evidence of rodent chewing/droppings. Systems are cooling perfect. Return duct for kitchen unit needs to be increased as we have a noise from air velocity. Returning Wednesday 8am to change ductwork for kitchen return.


Frank A.

Frank A. Job Checkin

Cowper Texas Veterans Home


Frank A.

Frank A. Job Checkin

Veterans home. Dryer vent cleaning.