Jacob L.

Jacob L. Job Checkin

AC Repair service provided for a residential customer near Oran Good Park. Found board to be functioning as designed. No need to replace board.


Jacob L.

Jacob L. Job Checkin

AC Repair - Springtime HVAC Repair for a residential homeowner near Brookhollow Estates. Found breaker tripped checked wiring on the system to ensure there was no obvious short or compromised wiring upon restating system compressor windings were compromised and the compressor popped releasing all refrigerant. The system is at critical failure no path for repair only recommendation at this time is for replacement. The homeowner is having guests Sunday and if possible would like the new system before then.


Jacob L.

Jacob L. Job Checkin

Springtime Thermostat Repair for a residential customer near Oran Good Park. Found thermostat to be semi functional. Replaced and confirmed function found C wire to not be sending 24v recommend replacing low voltage wire follow up.


Jacob L.

Jacob L. Job Checkin

Springtime Air Conditioning Maintenance for a residential customer near Webb Chapel Road. Inspected units for cooling, replaced all air filters and found condenser 3 to have a low capacitance run capacitor recommend replacement.


Jacob L.

Jacob L. Job Checkin

Spring Air Conditioning Installation for a commercial customer. Installation of a Trane 2 stage control board. Installed board and tested function system running as designed. Invoice pay link emailed to Amanda contact she said she will get it paid this morning once done on the phone.


Jacob L.

Jacob L. Job Checkin

Spring Residential Air Conditioning Repair Service. The technician arrived and found that the back right a/c unit was not running. The technician climbed onto the roof and ran a diagnostic of the unit. High voltage power was found to be working. Low voltage was found to be functioning at the transformer. 24 volts were found on R but no voltage was found on G. Board was not sending 24 volts to the contactor and therefore not engaging high voltage. The technician will need to contact tech support to confirm whether the board or thermostat is the cause of failure. A follow-up call will be scheduled ASAP. The thermostat was found to be functional however board was not sending out a command signal when prompted. Until a separate diagnostic board was used the system ran as designed. Board ordered will follow up with the customer when it arrives.


Tara R.

Tara R. Job Checkin

Install matching Goodman 16 SEER Condenser and Coil with 10 Year Parts Labor and Refrigerant Warranty


Javier  L.

Javier L. Job Checkin

Heater not working

Heater not working

Javier  L.

Javier L. Job Checkin

Replace drains as is, with single drain run to roof drain with condensate stands every 5 ft.


Tara R.

Tara R. Job Checkin

Indoor fan blower motor had to be rewired properly. Outside unit boardd and fan motor were both inop once replaced everything ran fine. Customer said parents will call to pay tomorrow.


SAMUEL H.

SAMUEL H. Job Checkin

Giving the customer a quote to replace 80 feet of 3/4 inch PVC as well as struts and correctly Pitch the drains


Kevin B.

Kevin B. Job Checkin

Installed 3 ton 410a tempstar rooftop package unit


Dale R.

Dale R. Job Checkin

Added 2 pounds r22 with sealnt for better cooling on trane 4ton system.


Rick M.

Rick M. Job Checkin

Technician Ricardo and Antonio found Rheem gas pack rooftop cooling system coil suffering from dirty sock syndrome will need to give prices on a cleaning solution