9006 Westfield Dr
Rowlett, TX 75088
(469) 476-4846

Our Top Cities


Local Reviews
for rockwall, tx

Rated 5.0 out of 5 stars based on 5 customer reviews

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always Great Service

Have used their service for three years and it's always easy to do, the service guys are polite and know what they're doing.

  • Overall Experience
  • Quality
  • Price
  • Convenience

ac service

Dale did a great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service & Second Opinion

I needed help with a problem that I had my other AC guy out for 3 times. I called Air Force One because I use them at home to see if they would do commercial work. The did and they were able to have a technician out the same day!! Not only was Kevin quick and friendly, he found the problem and got me a quote to fix it...all on the same day.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for rockwall, tx

josue_bazan56@hotmail.com

josue_bazan56@hotmail.com Job Checkin

Replaced control board for furnace. Tested system and it is blowing hot air now. No other issues found at this time. Customer signed up for presidential membership.


josue_bazan56@hotmail.com

josue_bazan56@hotmail.com Job Checkin

Need to return to replace circuit board. ICM282A. Also bring a 24X24X1 filter.


josue_bazan56@hotmail.com

josue_bazan56@hotmail.com Job Checkin

Quarterly Preventative Maintenance on 12 units


SAMUEL H.

SAMUEL H. Job Checkin

Up to 16 SEER 4 Ton Furnace with ECM Blower Motor


SAMUEL H.

SAMUEL H. Job Checkin

Diagnosed bad motherboard customer will reconvene with us on Monday to decide whether or not it is time for a new furnace or repair


Kevin B.

Kevin B. Job Checkin

High voltage wire going to carrier air handler was to small of wire for the amount of heating strips and burnt up. Cut back to bad wire and disconnected one heat strip tp allow system to operate safely.


Dale R.

Dale R. Job Checkin

Heating Check up 2 systems lennox furnace both systems are working great!!!


Kevin B.

Kevin B. Job Checkin

Replaced condenser fan motor and capacitor on rooftop carrier package unit


Dale R.

Dale R. Job Checkin

Replaced worn out contactor 1 pole and 5uf capacitor on upstairs condenser all working fine after fix..


Rick M.

Rick M. Job Checkin

TECHNICIAN RICK FOUND THAT THE SYSTEM HAS A FREON LEAK AT THE ON THE SUCTION LINE NEAR THE COMPRESSOR AND A CLOGGED THERMAL EXPANSION VALVE ON THE INSIDE COILS. SYSTEM USES THE OLD 410a FREON AND IT HAS ALL LEAKED OUT. REPAIR: - SYSTEM PUMP DOWN - REPAIR LEAK ON REFRIGERANT SUCTION LINE - ADD FILTER DRIER, AS NEEDED - CLEAN OUT INSIDE THERMAL EXPANSION VALVE - LEAK CHECK - CHARGE WITH 410aFREON - TEST SYSTEM

TECHNICIAN RICK FOUND THAT THE SYSTEM HAS A FREON LEAK AT THE ON THE SUCTION LINE NEAR THE COMPRESSOR AND A CLOGGED THERMAL EXPANSION VALVE ON THE INSIDE COILS. SYSTEM USES THE OLD 410a FREON AND IT HAS ALL LEAKED OUT.
REPAIR:
     - SYSTEM PUMP DOWN
     - REPAIR LEAK ON REFRIGERANT SUCTION LINE
     - ADD FILTER DRIER, AS NEEDED
     - CLEAN OUT INSIDE THERMAL EXPANSION VALVE 
     - LEAK CHECK
     - CHARGE WITH 410aFREON
     - TEST SYSTEM

Rick M.

Rick M. Job Checkin

Tech found system had been turning off on high head pressure outside, system needed to be water washed. Indoor filter still clean. Drain line still clean. Just need to water wash condensing unit outside every 30-90days. Also recommend to add stones around unit to help keep clean.


Rick M.

Rick M. Job Checkin

Rooftop condensing unit needs start kit replaced. Customer will change out him self


Rick M.

Rick M. Job Checkin

DIAGNOSTIC ANALYSIS -1 RESIDENTIAL SYSTEM. Found outside dual run cap bad, replaced 25/10/440. Need to water wash condensing unot every 30 - 60 days. Cleaned indoor evap coil all stopped up. Also need to add ptrap for airhandler.


Rick M.

Rick M. Job Checkin

Installed tstat clear cover lock box on one of the lobby thermostats


Rick M.

Rick M. Job Checkin

Replaced half horsepower 240 volt 1075 rpm blower motor on rooftop gas package system unit number 19 Suite number 207 old blower motor running slow causing slugging to compressor and not pulling all the heat from the air