Rated 5.0 out of 5 stars based on 4 customer reviews

Very thorough, Great service !

Jacob arrived on time and was very thorough with his inspection of our A/C unit. He explained everything about what he did and found.

  • Overall Experience
  • Quality
  • Price
  • Convenience

System Evaluation

My system quit cooling and outside unit wouldn't come on and was tripping the breakers. I contacted Air Force One was given a window of availability and Kevin came out at the start of that time window fast service, he checked out my system diagnosed the problem and provided options for replacing parts or the system. System replacement made more sense than throwing good money at an old system. New system cost wasn't that much more than replacing the outside unit that uses the old freon who know's how long that will remain available. I chose to go with a new system that's more efficient rather than limp along the old one. I hope to see electric bills go down with the new system too.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Had Wilson come out and check my system and they wanted $4k to replace the outside unit. I wanted a second opinion and Air Force One has fixed the problem for $120... They actually troubleshoot instead of trying to sell me a new unit. I have a new AC company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding

I have had the maintenance agreement for now the 4th year, and going on nine years for the equipment, and Air Force One has been exception from day one (Install, maintenance, issues). Kevin did a great job, appreciated.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for wylie, tx

SAMUEL H.

SAMUEL H. Job Checkin

Upon arrival found system to be off as well as low on refrigerant advise the customer about repairs she will relay to landlord


Tara R.

Tara R. Job Checkin

Inspection of inside unit revealed no faults. Outside dual run capacitor was found to be below the recommended threshold and was recommended for replacement.


Tara R.

Tara R. Job Checkin

Inside air handler fan wheel heavily caked with debris. Blower motor capacitor below standard capacitance. Outside unit heavily corroded and refrigerant pressures lower than normal. Customer requested a quote on upgrading to a new unit.


josue_bazan56@hotmail.com

josue_bazan56@hotmail.com Job Checkin

2 system spring PM. Units checked out good. No issues found at this time. Systems are ready for summer weather. Added customer supplied float switches to units. Units are operating normally.


SAMUEL H.

SAMUEL H. Job Checkin

system had a leak customer wanted to use his own refrigerant added leak stop system is working normal at this time wound the customer about the potential faults that might happen when we recharge the system


Rick M.

Rick M. Job Checkin

Technician ricordo performed diagnosis on a addict gas heating furnace found d the main heating limit at 140 degrees was stuck open causing bored to never kick the heating on customer said he would purchase it in house Monday morning otherwise jumped around safety switch tested everything else could not find any other issues once part has been replaced system should be ready for the cold winter thank you for your business from your tech ricardo moreno and Air Force One


Kevin B.

Kevin B. Job Checkin

Added compressor saver to trane condenser


Kevin B.

Kevin B. Job Checkin

Found carrier heat pump with a compressor shorted to ground, give customer solutions on replacement


Rick M.

Rick M. Job Checkin

ac not cool Notes added by tech Rick on 8/8/2015 10:06:05 PM Had to water wash condenaing coil. Notes added by tech Rick on 8/8/2015 10:08:52 PM Need to double check if we ever did any of the club maintenence on both units. ???


Rick M.

Rick M. Job Checkin

ac not cool Notes added by tech Rick on 8/8/2015 10:06:05 PM Had to water wash condenaing coil. Notes added by tech Rick on 8/8/2015 10:08:52 PM Need to double check if we ever did any of the club maintenence on both units. ???


Rick M.

Rick M. Job Checkin

DIAGNOSTIC ANALYSIS - RESIDENTIAL 410a handler has been txv changed to r22. System overcharged by 3lbs r22. Recoverd it. Txv sensing bilb installed backwards &/or upsidedown. Now freon level running @ charging chart from manufacture. Found on the outside units door.


Rick M.

Rick M. Job Checkin

DIAGNOSTIC ANALYSIS - RESIDENTIAL 410a handler has been txv changed to r22. System overcharged by 3lbs r22. Recoverd it. Txv sensing bilb installed backwards &/or upsidedown. Now frwfreon on level running @ charging chart from manufacture.


Rick M.

Rick M. Job Checkin

DIAGNOSTIC ANALYSIS - RESIDENTIAL 410a handler has been txv changed to r22. System overcharged by 3lbs r22. Recoverd it. Txv sensing bilb installed backwards &/or upsidedown. Now frwfreon on level running @ charging chart from manufacture.


Kevin B.

Kevin B. Job Checkin

Cooling Check of 2 rheem systems. Filters were clean, 20x25x1-2. Washed condenser coils, checked motors, capacitors and electrical. Declined blower motor capacitor. Checked r22 levels, normal. Both systems working properly.


Kevin B.

Kevin B. Job Checkin

Checked wiring on condenser fan motor for a carrier unit