A pond arrival found u/s not cooling found condenser wires all burnt up contactor not working, replaced wires and contactor. Then found fan motor not turning and replaced fan motor and 7.5 uf cap. Checked pressures and delta. Suggest maintenance yearly
Did a 2 system diamond winter maintenance tuneup in Plano TX. Checked blowers and capacitors, checked limits and safety’s, cleaned blowers, clean vacuum ports, cleaned flame sensors. Everything shows to be with in manufacture specs.
Did a 3 system winter maintenance tuneup plus plan in Plano TX. Checked blower motor and capacitors. Checked limits and safety’s, cleaned vacuum ports, cleaned flame sensors, checked furnace heating and “co” ppm 0 good, shared with customer about the air scrubber and left pamphlet with him.
Added new control board and system running properly found no other issues
Did a 1 winter maintenance tuneup plus plan, found new Lennox upflow furnace and found everything to be within manufacture specs. Checked limits and safety’s, checked amps and ohmns, cleaned flame sensor, cleaned vacuum port, checked variable blower and air flow. Checked heat rise of 47 ok. Talked about the air scrubber.
Did a 2 system winter maintenance tuneup plus plan one of the units are electrical and the other one is gas. There are 2 filters both were changed we checked limits and safety’s, amps and ohms on all motors, cleaned vacuum port, and cleaned flame sensor. The overall on both units meet the mfg specs. Both are heating properly.
Did a 1 system winter maintenance tuneup plus plan, changed filter, checked limits and safety’s, cleaned flame sensor, cleaned vacuum port, took delta.
Preformed two system heating preventive maintenance.
Water leaking issues resolved for a customer in Plano!